MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvc.2016.10.005

Медицинская библиотека · Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology · 2017

Aortoseptal angle and pressure gradient reduction following balloon valvuloplasty in dogs with severe subaortic stenosis.

Shen L, Estrada A H, Côté E, Powell M A, Winter B, Lamb K

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

To determine the relationship between aortoseptal angle (AoSA) and the short- and long-term systolic pressure gradient (PG) reduction following combined cutting and high-pressure balloon valvuloplasty (CB/HPBV) in dogs with severe subaortic stenosis.

ANIMALS: Retrospective study of 22 client-owned dogs of various breeds with severe subaortic stenosis (mean left ventricular to aortic PG = 143 mmHg; range = 80-322 mmHg) that underwent CB/HPBV.

MATERIALS AND

METHODS

Initial angiographic and left apical and right-sided parasternal long-axis view echocardiographic video loops were used for measuring the angle between the plane of the interventricular septum and the longitudinal axis of the ascending aorta. The PG reduction ratio immediately after CB/HPBV and 6 and 12 months later were compared with AoSA.

RESULTS

Weak correlations were observed for all instances of PG reduction ratio and AoSA type. Significantly greater mean differences of PG reduction ratio were observed for angles >160° than for angles <160° at 24 h (>160° mean: 54.45, standard error [SE]: ±3.8; <160° mean: 39.88, SE: ±2.09), 6 months (>160° mean: 57.73, SE: ±10.9; <160° mean: 28.22, SE: ±3.42), and 12 months (>160° mean: 76.11, SE: ±17.5; <160° mean: 27.61, SE: ±6.44; p=0.003).

CONCLUSIONS

Dogs with AoSA >160° on right-sided parasternal long-axis view echocardiograms responded with a greater PG reduction following CB/HPBV than did dogs with AoSA <160°. This suggests that AoSA is associated with long-term outcomes of CB/HPBV, and measurement could help in the evaluation of dogs that are candidates for CB/HPBV.

Для цитирования: Shen L, Estrada A H, Côté E, Powell M A, Winter B, Lamb K. Aortoseptal angle and pressure gradient reduction following balloon valvuloplasty in dogs with severe subaortic stenosis.. Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology. 2017. DOI: 10.1016/j.jvc.2016.10.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.