MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2021.113877

Медицинская библиотека · Biosensors & bioelectronics · 2021

Prediction of acute rejection in kidney transplanted patients based on the point-of-care isothermal molecular diagnostics platform.

Nguyen Van Dan, Van Nguyen Hau, Seo Jung Woo, Lee Sang Ho, Seo Tae Seok

СтатьяПеревод в очереди

Аннотация

In this study, we proposed an advanced point-of-care molecular diagnostic technology to evaluate the acute rejection (AR) in kidney transplanted patients. On the contrary to the conventional PCR method, we developed a colorimetric loop mediated isothermal amplification (LAMP) for quantitative analysis of the six biomarkers related to AR (CD3ϵ, IP-10, Tim-3-HAVCR2, CXCL9, PSMB9, C1QB) with a reference gene (18S rRNA). Using urinary cDNA samples of transplanted patients, it turned out that three biomarkers among six, namely IP-10, Tim-3-HAVCR2 and C1QB, have significant discrepancy in quantity between the stable graft (STA) patient and the AR patient. The AR prediction model using these three biomarkers was established, which could estimate the immune-rejection in the patients with 93.3% of accuracy. For the point-of-care (POC) molecular diagnostics for the AR evaluation, we constructed a centrifugal microfluidic platform, in which the RNA extraction from the clinical urinary samples, the quantitative reverse-transcription (RT)-LAMP reaction, and the data analysis based on the AR prediction model could be performed in a serial order. Ten blind clinical samples were analyzed on the POC genetic analyzer, showing 100% match with the validated qPCR data. Thus, the proposed advanced molecular diagnostic platform enables us to perform the timely treatment for the transplanted patients who are suffering from the allograft failure and side effects such as infection and malignancy.

Для цитирования: Nguyen Van Dan, Van Nguyen Hau, Seo Jung Woo, Lee Sang Ho, Seo Tae Seok. Prediction of acute rejection in kidney transplanted patients based on the point-of-care isothermal molecular diagnostics platform.. Biosensors & bioelectronics. 2021. DOI: 10.1016/j.bios.2021.113877.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.