MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.injury.2020.02.059

Медицинская библиотека · Injury · 2020

Is intramedullary screw fixation biomechanically superior to locking plate fixation and/or tension band wiring in transverse olecranon fractures? A cadaveric biomechanical comparison study.

Hahn Alexander, O'Hara Nathan N, Koh Kyung, Zhang Li-Qun, O'Toole Robert V, Andrew Eglseder W

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

To compare clinically important mechanical properties of three techniques used to fix transverse olecranon fractures (Arbeitsgemeinschaft fur Osteosynthesefragen and Orthopaedic Trauma Association class 2U1B1): (1) intramedullary (IM) screw, (2) locking plate, and (3) tension band wire in a realistic loading protocol using a cadaveric model.

METHODS

Fresh frozen cadaveric transverse olecranon fracture models were fixed with an IM screw (n = 6), a locking plate (n = 6), or a tension band (n = 6). Compression after fixation was recorded using a pressure sensor in the fracture before samples were loaded through the triceps tendon for 500 cycles of 0-500 N, assessing implant survival. The primary outcome measure was compression force before loading. The secondary outcome was frequency of implant failure defined as breakage of the implant itself or fracture gapping >5 mm. Binary outcomes were compared with χ2, and continuous variables were compared with unadjusted analysis of variance and a multivariable regression model adjusting for age, sex, dual-energy X-ray absorptiometry T-score, and testing order.

RESULTS

No statistically significant difference was shown in fracture compression between IM screw (mean, 162 N; 95% confidence interval [CI], 27-297 N), locking plate (mean, 125 N; 95% CI, -9-260 N), and tension band (mean, 163 N; 95% CI, 29-298 N) in unadjusted (p = 0.89) and adjusted (p = 0.82) analyses. A 100% implant failure rate was observed with tension band compared with 0% implant failure with IM screw or locking plate (p < 0.01).

CONCLUSION

We found no statistically significant differences in compression across the fracture site among techniques. We did find a higher risk of implant failure with tension band compared with IM screw and locking plate during cyclic loading in cadaveric bone.

Для цитирования: Hahn Alexander, O'Hara Nathan N, Koh Kyung, Zhang Li-Qun, O'Toole Robert V, Andrew Eglseder W. Is intramedullary screw fixation biomechanically superior to locking plate fixation and/or tension band wiring in transverse olecranon fractures? A cadaveric biomechanical comparison study.. Injury. 2020. DOI: 10.1016/j.injury.2020.02.059.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.