Comparison of hemodynamic effects of chest compression delivered via machine or human in asphyxiated piglets.

O'Reilly Megan, Lee Tze-Fun, Cheung Po-Yin, Schmölzer Georg M

СтатьяПеревод в очереди

Аннотация

BACKGROUND

High-quality chest compressions (CC) are an important factor of neonatal resuscitation. Mechanical CC devices may provide superior CC delivery and improve resuscitation outcomes. We aimed to compare the hemodynamic effects of CC delivered by machine and human using a neonatal piglet model.

METHODS

Twelve asphyxiated piglets were randomized to receive CC during resuscitation using an automated mechanical CC device ("machine") or the two-thumb encircling technique ("human"). CC was superimposed with sustained inflations.

RESULTS

Twelve newborn piglets (age 0-3 days, weight 2.12 ± 0.17 kg) were included in the study. Machine-delivered CC resulted in an increase in stroke volume, and minimum and maximum rate of left ventricle pressure change (dp/dtmin and dp/dtmax) compared to human-delivered CC.

CONCLUSIONS

During machine-delivered CC, stroke volume and left ventricular contractility were significantly improved. Mechanical CC devices may provide improved cardiopulmonary resuscitation outcomes in neonatal cardiac arrest induced by asphyxia.

IMPACT: Machine chest compression leads to changes in hemodynamic parameters during resuscitation of asphyxiated neonatal piglets, namely greater stroke volume and left ventricular contractility, compared with standard two-thumb compression technique. Mechanical chest compression devices may provide improved cardiopulmonary resuscitation outcomes in neonatal and pediatric asphyxia-induced cardiac arrest.

Для цитирования: O'Reilly Megan, Lee Tze-Fun, Cheung Po-Yin, Schmölzer Georg M. Comparison of hemodynamic effects of chest compression delivered via machine or human in asphyxiated piglets.. Pediatric research. 2023. DOI: 10.1038/s41390-023-02827-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.