MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/apmr.2002.34624

Медицинская библиотека · Archives of physical medicine and rehabilitation · 2002

The effectiveness of a hands-free environmental control system for the profoundly disabled.

Craig Ashley, Moses Perez, Tran Yvonne, McIsaac Paul, Kirkup Les

Клиническое исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To investigate the effectiveness of a hands-free environmental control system (ECS) that allows profoundly disabled persons to activate and control electric devices in their home by using consciously controlled changes in their brain signals.

DESIGN

A cohort study with a field trial testing of the ECS on 3 occasions.

SETTING

Participants' homes.

PARTICIPANTS

Ten profoundly disabled persons (mean age, 42.9 y), all of whom had very limited movement from the neck downward. Six had spinal cord injury with lesions ranging from C2 to C5-6. The other 4 had profound disability (1 each from polio, spinal muscular atrophy, multiple sclerosis, cerebral palsy).

INTERVENTIONS: Participants performed tasks on each of 3 test occasions. The tasks consisted of turning a television on at the beginning of the trial, changing channels (up, down), changing volume, and turning it off at the conclusion of each trial.

MAIN OUTCOME MEASURES: Time participants took to select the correct option and number of errors made in selecting the correct option. Measures were taken for each trial, so that any improvement in switching could be detected.

RESULTS

All participants effectively used the ECS to operate their television sets. Selecting a correct option took about 30 seconds (with the majority of this time attributed to machine cycling time), with an error rate of 1.8 per 5 options selected. The time taken to operate the ECS reduced slightly over the 3 trials and selection errors reduced by around 50% (to less than 1 error per 5 options).

CONCLUSIONS

With minimal training, profoundly disabled persons were able to use an ECS that uses changes in brain wave signals. This result demonstrates the efficacy of an additional and novel ECS in an area in which few switches are available.

Для цитирования: Craig Ashley, Moses Perez, Tran Yvonne, McIsaac Paul, Kirkup Les. The effectiveness of a hands-free environmental control system for the profoundly disabled.. Archives of physical medicine and rehabilitation. 2002. DOI: 10.1053/apmr.2002.34624.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.