Bilateral vocal cord paralysis after endoscopic placement of fully covered self-expandable metal stent for palliative treatment of malignant proximal esophageal obstruction: two case reports.

Chiche Y, Beltramo G, Degand T, Drouillard A, Foignot C, Baudouin N, Bonniaud P, Georges M

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Oesophageal stents have several well-known respiratory complications, including aspiration pneumonia, fistula and airway compression. However, bilateral vocal cord paralysis has rarely been described.

METHODS

We describe two patients who presented with refractory dysphagia due to malignant proximal oesophageal strictures. Both received palliative treatment consisting of fully covered self-expandable metal stents that were placed across the strictures.

RESULTS

Both patients developed inspiratory stridor and acute hypoxemic respiratory failure shortly after the stent was placed. Flexible bronchoscopy revealed vocal cord paralysis in paramedian position, potentially due to extrinsic compression of the posterior branch of the recurrent laryngeal nerve following the progressive opening of the esophageal prosthesis. One patient recovered after the stent was removed.

CONCLUSIONS

Bilateral vocal cord paralysis is a rare but potentially fatal complication of proximal esophagus stenting.

Для цитирования: Chiche Y, Beltramo G, Degand T, Drouillard A, Foignot C, Baudouin N, Bonniaud P, Georges M. Bilateral vocal cord paralysis after endoscopic placement of fully covered self-expandable metal stent for palliative treatment of malignant proximal esophageal obstruction: two case reports.. BMC gastroenterology. 2020. DOI: 10.1186/s12876-020-01300-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.