The Annals of thoracic surgery · 2012

Twenty-five year outcomes of tricuspid valve replacement comparing mechanical and biologic prostheses.

Сравнительное исследованиеСтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Garatti Andrea, Nano Giovanni, Bruschi Giuseppe, Canziani Alberto, Colombo Tiziano, Frigiola Alessandro, Martinelli Luigi, Menicanti Lorenzo

Аннотация

BACKGROUND: Tricuspid valve replacement (TVR) has historically been associated with high mortality and morbidity, and current knowledge of long-term results of TVR is limited. This study reviewed our experience from a consecutive series at 2 institutions.

METHODS: Ninety patients (65 women [72%]; mean age, 53.8 ± 14.2 years; mean body surface area, 1.6 ± 0.2 m(2)) underwent TVR between January 1980 and December 2005. The etiology was secondary to left-heart valve disease in 56 patients (62%), degenerative disease in 16 (18%), Ebstein anomaly in 7 (8%), and endocarditis in 11 (12%). Seventy patients (78%) were in New York Heart Association class III or IV. Sixty patients (67%) underwent redo procedures. TVR was with a mechanical valve in 46 patients (51%) and a biologic prosthesis in 44 (49%).

RESULTS: The overall operative mortality was 17.7% (16 patients). During follow-up, 16 of the 74 survivors died. Kaplan-Meier survival at 5, 10, and 15 years was, respectively, 72%, 65%, and 63%. During follow-up, 16 patients (21.6%) underwent reoperation; among them, 8 with a mechanical valve underwent reoperation for tricuspid valve thrombosis and 6 with a biologic prosthesis for tricuspid valve deterioration. However, freedom from reoperation at 5 and 10 years was similar between mechanical (86% and 76%) and bioprostheses (97% and 83%). All 16 patients survived the reoperation.

CONCLUSIONS: The present experience suggests that the type of implanted prosthesis in the tricuspid position does not affect early and long-term outcomes or the reoperation rate. Timely referral before end-stage cardiac impairment develops could determine further outcomes improvement.