MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2011.12.031

Медицинская библиотека · The Annals of thoracic surgery · 2012

Twenty-five year outcomes of tricuspid valve replacement comparing mechanical and biologic prostheses.

Garatti Andrea, Nano Giovanni, Bruschi Giuseppe, Canziani Alberto, Colombo Tiziano, Frigiola Alessandro, Martinelli Luigi, Menicanti Lorenzo

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Tricuspid valve replacement (TVR) has historically been associated with high mortality and morbidity, and current knowledge of long-term results of TVR is limited. This study reviewed our experience from a consecutive series at 2 institutions.

METHODS

Ninety patients (65 women [72%]; mean age, 53.8 ± 14.2 years; mean body surface area, 1.6 ± 0.2 m(2)) underwent TVR between January 1980 and December 2005. The etiology was secondary to left-heart valve disease in 56 patients (62%), degenerative disease in 16 (18%), Ebstein anomaly in 7 (8%), and endocarditis in 11 (12%). Seventy patients (78%) were in New York Heart Association class III or IV. Sixty patients (67%) underwent redo procedures. TVR was with a mechanical valve in 46 patients (51%) and a biologic prosthesis in 44 (49%).

RESULTS

The overall operative mortality was 17.7% (16 patients). During follow-up, 16 of the 74 survivors died. Kaplan-Meier survival at 5, 10, and 15 years was, respectively, 72%, 65%, and 63%. During follow-up, 16 patients (21.6%) underwent reoperation; among them, 8 with a mechanical valve underwent reoperation for tricuspid valve thrombosis and 6 with a biologic prosthesis for tricuspid valve deterioration. However, freedom from reoperation at 5 and 10 years was similar between mechanical (86% and 76%) and bioprostheses (97% and 83%). All 16 patients survived the reoperation.

CONCLUSIONS

The present experience suggests that the type of implanted prosthesis in the tricuspid position does not affect early and long-term outcomes or the reoperation rate. Timely referral before end-stage cardiac impairment develops could determine further outcomes improvement.

Для цитирования: Garatti Andrea, Nano Giovanni, Bruschi Giuseppe, Canziani Alberto, Colombo Tiziano, Frigiola Alessandro, Martinelli Luigi, Menicanti Lorenzo. Twenty-five year outcomes of tricuspid valve replacement comparing mechanical and biologic prostheses.. The Annals of thoracic surgery. 2012. DOI: 10.1016/j.athoracsur.2011.12.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.