Small wire external fixation for high-energy tibial plateau fractures.
Аннотация
PURPOSE: To assess results of small wire external fixation using a ligamentotaxis technique for high-energy tibial plateau fractures.
METHODS
Between April 2002 and May 2004, 38 consecutive patients aged 21 to 60 (mean, 32) years underwent small wire external fixation for high-energy tibial plateau fractures. 15 involved the right and 23 the left knee. 34 were closed and 4 were open injuries. Fractures were classified according to Schatzker's staging system. After a minimal of 2 years' follow-up (range, 24-42 months), each affected knee was evaluated using Rasmussen's (1) 30-point clinical grading system and (2) radiological evaluation.
RESULTS
There were 22 type-VI and 16 type-V Schatzker tibial plateau fractures. Complications consisted of: 2 superficial infections, 3 pin site infections, and 4 peroneal nerve palsies. No soft tissue necrosis or devitalisation occurred. The mean range of knee movement was 132 degrees. The mean Rasmussen radiological score was 14 (range, 10-18): excellent in 6, good in 26, and fair in 6. The mean Rasmusssen functional score was 26 (range, 17-30): excellent in 19 patients, good in 17, and fair in 2. Clinical results did not parallel the radiological results.
CONCLUSION
Small wire external fixation allows anatomical reconstruction of the articular surface, stable fixation of fracture fragments, early movement of the joint, and care of associated soft tissue injuries, without a high rate of complications.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.