MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3233/thc-2009-0544

Медицинская библиотека · Technology and health care : official journal of the European Society for Engineering and Medicine · 2009

3D visualized robot assisted reduction of femoral shaft fractures: evaluation in exposed cadaveric bones.

Oszwald Markus, Westphal Ralf, Bredow Jan, Gaulke Ralph, O'Loughlin P F, Huefner Tobias, Wahl Friedrich, Krettek Christian, Goesling Thomas

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The main problems in intra-medullary nailing of femoral shaft-fractures are leg-length discrepancies and rotational differences with an incidence of 2-18% and 20-40% respectively. These may lead to severe postoperative sequelae such as additional correctional operations and difficult rehabilitation. Insufficient visualization can be considered the main reason for these complications. Finally, retention of the fragments in the correct alignment before nail insertion is difficult. To overcome these problems we established a robotic telemanipulator system to support the reduction process. It was evaluated in 30 fractures of embalmed human femora. Specially programmed software used an image-dataset which was acquired by an isocentric 3D fluoroscope. For visualization, a surface projection was generated. Localization and tracking of the fragments and the robot-arm as well as accuracy measurement was performed by using an optical navigation system. Manipulation was controlled via a force-feedback joystick. This way, collisions of the fragments were transmitted back to the surgeon. At the end of the reduction the robot could rigidly retain the fragments' position.

Для цитирования: Oszwald Markus, Westphal Ralf, Bredow Jan, Gaulke Ralph, O'Loughlin P F, Huefner Tobias, Wahl Friedrich, Krettek Christian, Goesling Thomas. 3D visualized robot assisted reduction of femoral shaft fractures: evaluation in exposed cadaveric bones.. Technology and health care : official journal of the European Society for Engineering and Medicine. 2009. DOI: 10.3233/thc-2009-0544.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.