OBJECTIVE

Intracranial pressure (ICP) monitoring is widely used in the management of patients with traumatic brain injury (TBI). The morphology of the ICP waveform is considered to provide valuable insights into cerebrospinal compliance. This paper proposes a topological data analysis (TDA)-based methodology for ICP morphological analysis.

METHODS

About 1.2 million ICP waveforms from 60 TBI patients are utilized to construct a data map. This map is used for near real-time ICP morphology classification, subpeak identification, and Big Data visualization. The method allows ICP morphology class labels and subpeak labels annotated by SMEs on a subset of representative waveforms to quickly propagate to millions of unlabeled waveforms, which significantly reduces labelling effort.

RESULTS

The proposed visualization allows the overlay of various ICP morphological features (e.g., P2/P1 ratio, ICP peak pressure) to provide insights into patients' physiological condition. The method is validated on 10,000 ICP waveforms from 10 patients, achieving an overall waveform classification accuracy of 96.1% and subpeak identification accuracy of 97.3% .

CONCLUSION

The proposed method can track subtle changes in ICP waveform morphology, offering insight into evolving intracranial compliance beyond mean ICP values. By enabling real-time, interpretable monitoring, the method provides a tool to support individualized management and early intervention in TBI patient care.

Для цитирования: Han Xu, Suer Alex, Foreman Brandon, Jia Xiaodong. Topological Visualization of Intracranial Pressure Morphology Variations and Real Time Data Trajectory Mapping.. IEEE journal of biomedical and health informatics. 2026. DOI: 10.1109/jbhi.2025.3621411.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.