International journal of clinical and experimental pathology · 2015
Combined evaluation of adenosine deaminase level and histopathological findings from pleural biopsy with Cope's needle for the diagnosis of tuberculous pleurisy.
Сравнительное исследованиеОценочное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Behrsin Rodolfo Fred, Junior Cyro Teixeira da Silva, Cardoso Gilberto Perez, Barillo Jorge Luiz, de Souza Joeber Bernardo Soares, de Araújo Elizabeth Giestal
Аннотация
INTRODUCTION: Closed needle pleural biopsy (CNPB) has historically been the gold standard procedure for the diagnosis of pleural tuberculosis. Adenosine deaminase (ADA) is an efficient biomarker for tuberculosis that is measurable in pleural fluids.
OBJECTIVE: We compared the diagnostic accuracy of the pleural ADA (P-ADA) level and histopathological findings of CNPB specimens in patients with pleural tuberculosis.
METHODS: This prospective study consisted of two groups of examinations with a proven diagnosis of pleural effusion. The P-ADA level was measured in 218 patients with pleural effusion due to a number of causes, and 157 CNPB specimens underwent histopathological analysis.
RESULTS: CNPBs were performed in patients with tuberculosis (n=122) and other diseases: adenocarcinoma (n=23), lymphoma (n=5), systemic lupus erythematosus (n=4), squamous cell carcinoma (n=2), and small cell lung cancer (n=1). According to the ROC curve, the optimal cut-off value of the P-ADA level (Giusti and Galanti colorimetric method) was equal to or greater than 40.0 U/L. The diagnostic accuracy of the P-ADA test was 83.0%, and that of histopathological examination of the CNPB tissue, was 78.8% (AUC=0.293, P=0.7695). The association between the P-ADA assay and pleural histopathology was 24.41 (P<0.0001). The tetrachoric correlation coefficient was 0.563 (high correlation).
CONCLUSION: In Brazil and other countries with a high incidence of tuberculosis, P-ADA activity is an accurate test for the diagnosis of tuberculous pleural effusions, and its use should be encouraged. The high diagnostic performance of the P-ADA test could to aid the diagnosis of pleural tuberculosis and render CNPB unnecessary.
OBJECTIVE: We compared the diagnostic accuracy of the pleural ADA (P-ADA) level and histopathological findings of CNPB specimens in patients with pleural tuberculosis.
METHODS: This prospective study consisted of two groups of examinations with a proven diagnosis of pleural effusion. The P-ADA level was measured in 218 patients with pleural effusion due to a number of causes, and 157 CNPB specimens underwent histopathological analysis.
RESULTS: CNPBs were performed in patients with tuberculosis (n=122) and other diseases: adenocarcinoma (n=23), lymphoma (n=5), systemic lupus erythematosus (n=4), squamous cell carcinoma (n=2), and small cell lung cancer (n=1). According to the ROC curve, the optimal cut-off value of the P-ADA level (Giusti and Galanti colorimetric method) was equal to or greater than 40.0 U/L. The diagnostic accuracy of the P-ADA test was 83.0%, and that of histopathological examination of the CNPB tissue, was 78.8% (AUC=0.293, P=0.7695). The association between the P-ADA assay and pleural histopathology was 24.41 (P<0.0001). The tetrachoric correlation coefficient was 0.563 (high correlation).
CONCLUSION: In Brazil and other countries with a high incidence of tuberculosis, P-ADA activity is an accurate test for the diagnosis of tuberculous pleural effusions, and its use should be encouraged. The high diagnostic performance of the P-ADA test could to aid the diagnosis of pleural tuberculosis and render CNPB unnecessary.