DOI 10.1080/17501911.2025.2544530
High-throughput assessment of FMR1 and SNRPN methylation-based newborn screening using IsoPure and QIAcube HT systems.
Аннотация
AIM: This study compared methylation-specific quantitative melt analysis of FMR1 and SNRPN methylation (mDNA) using automated bisulfite conversion by the magnetic-bead-based IsoPure and column-based QIAcube HT systems.
METHODS
Two bisulfite conversion methods were assessed on 3.2 mm punches from the same archival blood spots stored at room temperature for >10 years of individuals with FMR1 premutation (n = 20), fragile X syndrome (FXS, n = 20), or chromosome 15 imprinting disorders (n = 50) and freshly made blood spots from 184 newborns from the general population. Performance criteria were: (i) diagnostic sensitivity and specificity for the conditions screened; (ii) reaction failure rate; (iii) variability in mDNA between groups.
RESULTS
Both methods showed 100% sensitivity and specificity for differentiating FXS and individual chromosome 15 imprinting disorders. IsoPure showed reaction failure rates of 0.365% for SNRPN and 0.74% for FMR1 compared to 19.34% and 2.56%, for QIAcube HT, respectively, with most failed reactions originating from archival blood spots. IsoPure showed lower variability in mDNA values in the neurotypical and condition-specific ranges.
CONCLUSION
The IsoPure system showed superior performance especially on archival samples, with broader applications for screening and diagnostic testing requiring high-throughput mDNA analyses on materials of limited quantity and quality.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.