MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13756-023-01273-5

Медицинская библиотека · Antimicrobial resistance and infection control · 2023

Using adenosine triphosphate bioluminescence level monitoring to identify bacterial reservoirs during two consecutive Enterococcus faecium and Staphylococcus capitis nosocomial infection outbreaks at a neonatal intensive care unit.

Kim Ye Ji, Hong Min Yeong, Kang Hyun Mi, Yum Sook Kyung, Youn Young Ah, Lee Dong-Gun, Kang Jin Han

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

This study aimed to assess the role of adenosine triphosphate (ATP) bioluminescence level monitoring for identifying reservoirs of the outbreak pathogen during two consecutive outbreaks caused by Enterococcus faecium and Staphylococcus capitis at a neonatal intensive care unit (NICU). The secondary aim was to evaluate the long-term sustainability of the infection control measures employed one year after the final intervention measures.

METHODS

Two outbreaks occurred during a 53-day period in two disconnected subunits, A and B, that share the same attending physicians. ATP bioluminescence level monitoring, environmental cultures, and hand cultures from healthcare workers (HCW) in the NICU were performed. Pulsed-field gel electrophoresis (PFGE) typing was carried out to investigate the phylogenetic relatedness of the isolated strains.

RESULTS

Four cases of E. faecium sepsis (patients A-8, A-7, A-9, B-8) and three cases of S. capitis sepsis (patients A-16, A-2, B-8) were diagnosed in six preterm infants over a span of 53 days. ATP levels remained high on keyboard 1 of the main station (2076 relative light unit [RLU]/100 cm2) and the keyboard of bed A-9 (4886 RLU/100 cm2). By guidance with the ATP results, environmental cultures showed that E. faecium isolated from the patients and from the main station's keyboard 1 were genotypically indistinguishable. Two different S. capitis strains caused sepsis in three patients. A total 77.8% (n = 7/9) of S. capitis cultured from HCW's hands were genotypically indistinguishable to the strains isolated from A-2 and A-16. The remaining 22.2% (n = 2/9) were genotypically indistinguishable to patient B-8. Three interventions to decrease the risk of bacterial transmission were applied, with the final intervention including a switch of all keyboards and mice in NICU-A and B to disinfectable ones. Post-intervention prospective monitoring up to one year showed a decrease in blood culture positivity (P = 0.0019) and catheter-related blood stream infection rate (P = 0.016) before and after intervention.

CONCLUSION

ATP monitoring is an effective tool in identifying difficult to disinfect areas in NICUs. Non-medical devices may serve as reservoirs of pathogens causing nosocomial outbreaks, and HCWs' hands contribute to bacterial transmission in NICUs.

Для цитирования: Kim Ye Ji, Hong Min Yeong, Kang Hyun Mi, Yum Sook Kyung, Youn Young Ah, Lee Dong-Gun, Kang Jin Han. Using adenosine triphosphate bioluminescence level monitoring to identify bacterial reservoirs during two consecutive Enterococcus faecium and Staphylococcus capitis nosocomial infection outbreaks at a neonatal intensive care unit.. Antimicrobial resistance and infection control. 2023. DOI: 10.1186/s13756-023-01273-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.