Intermittently scanned continuous glucose monitoring provides no benefit over structured self-monitoring of blood glucose in type 2 diabetes not on prandial insulin, in the context of diabetes self-management education: GLucose monitoring programme SingaporE (GLiMPSE).

Rama Chandran Suresh, Rahman Nabilah, Gandhi Mihir, Tan Ngiap Chuan, Phoon Ian K Y, Seah Darren E J, Cheah Ming Hann, Sek Kathleen, Gardner Daphne Su-Lyn

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

We evaluated the impact of intermittently scanned continuous glucose monitoring(is-CGM)over self-monitoring of blood glucose(SMBG) in the context of diabetes self-management education (DSME) in sub-optimally controlled type 2 diabetes(T2D) in a multi-ethnicsetting.

RESEARCH DESIGN AND METHOD: Randomized-controlled, open-label trial (NCT04564911), of T2D with HbA1c ≥ 7.5-≤10 %, on oral agents with/without basal insulin was carried out. Intervention arm received 6 weeks(w) continuous is-CGM, followed by one is-CGM/month till 24w. Control arm was advised to perform 4 SMBG/day. Educationwas delivered at weeks 0, 2, 8, 16.

PRIMARY OUTCOME: Change in HbA1c from baseline at 24w. Modified intention-to-treat (mITT) analysis with linear mixed-effect model for repeated measurementswas performed.

RESULTS

176 subjects, age 55 ± 10.7 years(y), DM duration 11 ± 7.3y, BMI 27.8 ± 5.9 kg/m2, 58 % Male, 29.5 % basal insulin users were analysed. Within each arm,from baseline to 24w, mean HbA1c decreasedby -0.6 % (-6.6.mmol/mol, p-value < 0.01)and weight decreased(isCGM: -1.44 kg; SMBG: -1.25 kg, both p < 0.01). These changes were sustained to one year. However, there wasno significant difference in these parameters between arms (p-value > 0.05).

CONCLUSION

In the context of DSME, use of either SMBG or is-CGM led to improved glycaemia and reduced weight over a period of 24 weeks, sustained to one year.

Для цитирования: Rama Chandran Suresh, Rahman Nabilah, Gandhi Mihir, Tan Ngiap Chuan, Phoon Ian K Y, Seah Darren E J, Cheah Ming Hann, Sek Kathleen, Gardner Daphne Su-Lyn. Intermittently scanned continuous glucose monitoring provides no benefit over structured self-monitoring of blood glucose in type 2 diabetes not on prandial insulin, in the context of diabetes self-management education: GLucose monitoring programme SingaporE (GLiMPSE).. Diabetes research and clinical practice. 2024. DOI: 10.1016/j.diabres.2024.111678.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.