MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0886-3350(13)80067-3

Медицинская библиотека · Journal of cataract and refractive surgery · 1992

Effect of posterior chamber intraocular lens design and surgical placement on postoperative outcome.

Martin R G, Sanders D R, Souchek J, Raanan M G, DeLuca M

Клиническое исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

Intraocular lens (IOL) design, optical configuration, and placement have potential effects on postoperative outcome. Laboratory studies have suggested that one-piece, biconvex designs may reduce or delay posterior capsular opacification and that in-the-bag fixation of the posterior chamber IOL may reduce inflammation. To document the clinical significance of IOL design and placement, we conducted a randomized, prospective, clinical trial. Six hundred uncomplicated capsulorhexis and phacoemulsification patients were randomized in a three-factor design to receive an IOL that was one-piece or three-piece, had a biconvex, plano-convex, or laser ridge optic, and was bag-or sulcus-fixated. Treatment differences were related to lens placement. Patients with bag-fixated IOLs had less posterior capsular opacification, fewer YAG laser capsulotomies, a higher percentage of centered lenses, less inflammation, and fewer late posterior capsular striae than those with sulcus-fixated IOLs. In the latter group, patients with three-piece IOLs had fewer posterior capsular striae at three months postoperatively. All six occurrences of haptic loop distortion were in patients with three-piece IOLs. Patients with the one-piece design had less late inflammation than those with the three-piece design. Fewer YAG capsulotomies were necessary at one year in patients with the biconvex design than in those with the plano-convex or laser ridge configurations. Operative complications, endothelial cell loss, and postoperative complications were not IOL-related.

Для цитирования: Martin R G, Sanders D R, Souchek J, Raanan M G, DeLuca M. Effect of posterior chamber intraocular lens design and surgical placement on postoperative outcome.. Journal of cataract and refractive surgery. 1992. DOI: 10.1016/s0886-3350(13)80067-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.