MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2023.02.052

Медицинская библиотека · Journal of the American College of Cardiology · 2023

Improved Outcomes After Pulmonary Valve Replacement in Repaired Tetralogy of Fallot.

Bokma Jouke P, Geva Tal, Sleeper Lynn A, Lee Ji Hae, Lu Minmin, Sompolinsky Tehila, Babu-Narayan Sonya V, Wald Rachel M, Mulder Barbara J M, Valente Anne Marie

Многоцентровое исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The impact of pulmonary valve replacement (PVR) on major adverse clinical outcomes in patients with repaired tetralogy of Fallot (rTOF) is unknown.

OBJECTIVES

The purpose of this study was to determine whether PVR is associated with improved survival and freedom from sustained ventricular tachycardia (VT) in rTOF.

METHODS

A PVR propensity score was created to adjust for baseline differences between PVR and non-PVR patients enrolled in INDICATOR (International Multicenter TOF Registry). The primary outcome was time to the earliest occurrence of death or sustained VT. PVR and non-PVR patients were matched 1:1 on PVR propensity score (matched cohort) and in the full cohort, modeling was performed with propensity score as a covariate adjustment.

RESULTS

Among 1,143 patients with rTOF (age 27 ± 14 years, 47% PVR, follow-up 8.3 ± 5.2 years), the primary outcome occurred in 82. The adjusted HR for the primary outcome for PVR vs no-PVR (matched cohort n = 524) was 0.41 (95% CI: 0.21-0.81; multivariable model P = 0.010). Full cohort analysis revealed similar results. Subgroup analysis suggested beneficial effects in patients with advanced right ventricular (RV) dilatation (interaction P = 0.046; full cohort). In patients with RV end-systolic volume index >80 mL/m2, PVR was associated with a lower primary outcome risk (HR: 0.32; 95% CI: 0.16-0.62; P < 0.001). There was no association between PVR and the primary outcome in patients with RV end-systolic volume index ≤80 mL/m2 (HR: 0.86; 95% CI: 0.38-1.92; P = 0.70).

CONCLUSIONS

Compared with rTOF patients who did not receive PVR, propensity score-matched individuals receiving PVR had lower risk of a composite endpoint of death or sustained VT.

Для цитирования: Bokma Jouke P, Geva Tal, Sleeper Lynn A, Lee Ji Hae, Lu Minmin, Sompolinsky Tehila, Babu-Narayan Sonya V, Wald Rachel M, Mulder Barbara J M, Valente Anne Marie. Improved Outcomes After Pulmonary Valve Replacement in Repaired Tetralogy of Fallot.. Journal of the American College of Cardiology. 2023. DOI: 10.1016/j.jacc.2023.02.052.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.