MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/00913847.2020.1796182

Медицинская библиотека · The Physician and sportsmedicine · 2020

Sport-related femoral artery occlusion detected by near-infrared spectroscopy and pedal power measurements: a case report.

van Hooff Martijn, Schep Goof, Bender Mart, Scheltinga Marc, Savelberg Hans

Клинический случайСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

Approximately one in five professional cycling athletes will eventually develop a sport-related vascular problem. However, detecting such flow limitation is a diagnostic challenge as the sensitivity of the currently available standard diagnostic tools is limited.

METHODS

Here we present an athlete with exercise-induced pain and weakness of the left leg. During the physical examination, pulsations of the femoral artery were palpable but less prominent. He was analyzed in an ongoing research project aimed at improving methods detecting sport-related leg flow limitations.

RESULTS

During functional testing, the ankle-brachial index of the left leg was moderately lowered. However, results of near-infrared spectroscopy and pedal power measurements were largely abnormal suggesting a severe flow limitation.

CONCLUSION

Combining post-exercise ankle-brachial index, near-infrared spectroscopy, and pedal power measurements as routine diagnostic functional testing suggested a severe arterial flow inflow limitation. Conventional diagnostics encompassing duplex-Doppler echography and magnetic resonance angiography confirmed a femoral artery occlusion.

CLINICAL TRIAL REGISTRATION: https://www.trialregister.nl/ identifier is Trial NL8557.Abbreviations: NIRS: Near-Infrared Spectroscopy; PPM: Pedal Power Measurements; ABI: Ankle Brachial Index; PSV: Peak Systolic Velocity.

Для цитирования: van Hooff Martijn, Schep Goof, Bender Mart, Scheltinga Marc, Savelberg Hans. Sport-related femoral artery occlusion detected by near-infrared spectroscopy and pedal power measurements: a case report.. The Physician and sportsmedicine. 2020. DOI: 10.1080/00913847.2020.1796182.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.