Large coronal shear fractures of the capitellum and trochlea treated with headless compression screws.

Mighell Mark, Virani Nazeem A, Shannon Robert, Echols Eddy L, Badman Brian L, Keating Christopher J

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The purpose of this study is to retrospectively evaluate the clinical outcomes of 18 patients with large coronal shear fractures of the capitellum and lateral trochlea that underwent open reduction and internal fixation with headless compression screws.

METHODS

Eighteen patients were identified (16 women, 2 men) with an average age of 45 years and an average follow-up of 26 months. Fractures were classified according to the Dubberley classification as 11 type-1A injuries and 7 type-2A injuries.

RESULTS

All patients, with the exception of 1, had good to excellent functional results by the Broberg-Morrey scale (mean score, 93.3). Average arc of motion was 128 degrees in flexion/extension and 176 degrees in pronation/supination. Radiographically, 3 patients had subsequent development of avascular necrosis and 5 developed arthrosis. No significant negative correlation was noted between the development of avascular necrosis and clinical outcome. Minor complications occurred in 2 patients, but there were no re-operations.

CONCLUSION

Headless compression screw fixation allows for stable fixation in patients with large coronal shear fractures of the distal humerus without posterior comminution.

LEVEL OF EVIDENCE: 4.

Для цитирования: Mighell Mark, Virani Nazeem A, Shannon Robert, Echols Eddy L, Badman Brian L, Keating Christopher J. Large coronal shear fractures of the capitellum and trochlea treated with headless compression screws.. Journal of shoulder and elbow surgery. 2010. DOI: 10.1016/j.jse.2009.05.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.