MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/08927790261451054

Медицинская библиотека · Journal of endourology · 2026

Are Two Channels Better than One? A Comparative Study Between Dual-Lumen and Single-Lumen Flexible Ureteroscope in Retrograde Intrarenal Surgery.

Diamantidis Dimitrios, Chrysikos Michael N, Toufas George, Georgellis Chrysostomos, Giannopoulos Stavros, Tsakaldimis Georgios, Kalaitzis Christos, Giannakopoulos Stilianos

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To compare perioperative efficiency, stone-free rates, and safety between a dual-lumen and a single-lumen flexible ureteroscope in retrograde intrarenal surgery (RIRS).

MATERIALS AND

METHODS

This comparative study included 80 consecutive patients with a single renal stone 1.0-1.5 cm in the pelvicalyceal system treated with RIRS using either a dual-lumen ureteroscope (Group A, n = 40) or a single-lumen ureteroscope (Group B, n = 40). Recorded outcomes included operative and fluoroscopy times, failure of ureteral access sheath (UAS) insertion, surgeon-rated clarity of vision (0-10 scale), stone-free status on non-contrast computed tomography at 30 days, and complications graded by the Clavien-Dindo system and the Post-Ureteroscopy Lesion Scale (PULS). The stone-free rate (SFR) was defined as absolute and relative.

RESULTS

Baseline demographics, stone size, and stone location were comparable between groups. Dual-lumen use was associated with shorter operative time (38.6 ± 9.3 vs 52.7 ± 8.1 minutes, p = 0.018), shorter fluoroscopy time (23.6 ± 5.5 vs 34.2 ± 4.7 seconds, p = 0.04), and higher clarity-of-vision scores (8.6 ± 1.35 vs 5.9 ± 1.86, p = 0.035). UAS insertion failed more often with the dual-lumen scope (20.0% vs 10.0%, p = 0.32). One month after evaluation, SFR did not significantly differ between the two groups. Postoperative complications were infrequent (12.5% vs 10.0%, p = 0.72), all were Clavien-Dindo grade I-II, and no PULS grade ≥4 ureteral injuries occurred.

CONCLUSIONS

Compared with a reusable single-lumen ureteroscope, the dual-lumen device improved operative efficiency in terms of shorter operative and fluoroscopy time and better clarity of vision. These benefits are counterbalanced by a higher UAS insertion failure rate related to the larger outer diameter of the ureteroscope.

Для цитирования: Diamantidis Dimitrios, Chrysikos Michael N, Toufas George, Georgellis Chrysostomos, Giannopoulos Stavros, Tsakaldimis Georgios, Kalaitzis Christos, Giannakopoulos Stilianos. Are Two Channels Better than One? A Comparative Study Between Dual-Lumen and Single-Lumen Flexible Ureteroscope in Retrograde Intrarenal Surgery.. Journal of endourology. 2026. DOI: 10.1177/08927790261451054.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.