DOI 10.1053/jcan.2000.18323

Медицинская библиотека · Journal of cardiothoracic and vascular anesthesia · 2000

Gastric tonometer monitoring in infants undergoing repair of coarctation of the aorta.

Soybir N, Tekin S, Koner O, Arat S, Karaoglu K, Sarioglu T

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate gastric tonometer monitoring for splanchnic hypoperfusion in infants during surgical intervention for aortic coarctation, especially within aortic cross-clamp periods.

DESIGN

A prospective study.

SETTING

Cardiovascular intensive care unit in a university hospital.

PARTICIPANTS

Fourteen infant patients after elective, uncomplicated repair of coarctation of the aorta.

INTERVENTIONS: After the anesthesia induction, a 7F tonometry catheter was inserted into the stomach oropharyngeally. Gastric carbon dioxide, arterial blood gases, blood pressure of upper extremities, and hematocrit values were measured in 5 different time intervals. Time periods were as follows: T1 (after the anesthesia induction), T2 (before aortic cross-clamp), T3 (immediately after aortic cross-clamp removal), T4 (40 minutes after aortic cross-clamp removal), and T5 (as the patient reached the intensive care unit). Intramucosal pH was measured by means of the Henderson-Hasselbach equation. The mean values of all parameters were calculated. According to T1 time, T2, T3, T4, and T5 times were compared with Student's t-test.

MEASUREMENTS AND MAIN

RESULTS

Mean aortic cross-clamp time was 19.4 +/- 6.6 minutes. Intramucosal pH values of T3 (p < 0.001) and T4 (p < 0.01) were found to be lower than values of T1. The gastric carbon dioxide values of T3 were significantly higher than T1 (p < 0.01), and bicarbonate and arterial pH values of T3 were significantly lower (p < 0.01). There were no significant differences in other parameters over time intervals.

CONCLUSION

Splanchnic hypoperfusion exists during aortic cross-clamping in infant aortic coarctation surgery, and the tonometric catheter is considered to be a safe method for monitoring this hypoperfusion.

Для цитирования: Soybir N, Tekin S, Koner O, Arat S, Karaoglu K, Sarioglu T. Gastric tonometer monitoring in infants undergoing repair of coarctation of the aorta.. Journal of cardiothoracic and vascular anesthesia. 2000. DOI: 10.1053/jcan.2000.18323.

Предметные рубрики MeSH