MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1364/oe.20.004159

Медицинская библиотека · Optics express · 2012

Optoacoustic monitoring of cerebral venous blood oxygenation though intact scalp in large animals.

Petrov I Y, Petrov Y, Prough D S, Cicenaite I, Deyo D J, Esenaliev R O

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Monitoring (currently invasive) of cerebral venous blood oxygenation is a key to avoiding hypoxia-induced brain injury resulting in death or severe disability. Noninvasive, optoacoustic monitoring of cerebral venous blood oxygenation can potentially replace existing invasive methods. To the best of our knowledge, we report for the first time noninvasive monitoring of cerebral venous blood oxygenation through intact scalp that was validated with invasive, "gold standard" measurements. We performed an in vivo study in the sheep superior sagittal sinus (SSS), a large midline cerebral vein, using our novel, multi-wavelength optoacoustic system. The study results demonstrated that: 1) the optoacoustic signal from the sheep SSS is detectable through the thick, intact scalp and skull; 2) the SSS signal amplitude correlated well with wavelength and actual SSS blood oxygenation measured invasively using SSS catheterization, blood sampling, and measurement with "gold standard" CO-Oximeter; 3) the optoacoustically predicted oxygenation strongly correlated with that measured with the CO-Oximeter. Our results indicate that monitoring of cerebral venous blood oxygenation may be performed in humans noninvasively and accurately through the intact scalp using optoacoustic systems because the sheep scalp and skull thickness is comparable to that of humans whereas the sheep SSS is much smaller than that of humans.

Для цитирования: Petrov I Y, Petrov Y, Prough D S, Cicenaite I, Deyo D J, Esenaliev R O. Optoacoustic monitoring of cerebral venous blood oxygenation though intact scalp in large animals.. Optics express. 2012. DOI: 10.1364/oe.20.004159.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.