MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2023.04.015

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2023

Long-term outcomes of tetralogy of Fallot repair: A 30-year experience with 960 patients.

Ishigami Shuta, Ye Xin Tao, Buratto Edward, Ivanov Yaroslav, Chowdhuri Kuntal Roy, Fulkoski Nick, Robertson Terry, Davies Ben, Brizard Christian P, Konstantinov Igor E

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

This study evaluates the long-term results of tetralogy of Fallot repair and assesses the risk factors for adverse outcomes.

METHODS

This retrospective study included 960 patients who underwent transatrial transpulmonary tetralogy of Fallot repair between 1990 and 2020.

RESULTS

A transannular patch was placed in 722 patients, and pulmonary valve preservation was achieved in 233 patients. The median age at tetralogy of Fallot repair was 9.4 (interquartile range, 6.2-14.2) months. The median follow-up duration was 10.6 (interquartile range, 5.4-16.3) years. There were 8 early deaths (0.8%) and 20 late deaths (2.1%). Genetic syndrome and pulmonary valve annulus Z score less than -3 were risk factors for mortality. The survival was 97.7% (95% confidence interval, 96.4-98.5) and 94.5% (95% confidence interval, 90.9-96.7) at 10 and 30 years, respectively. Freedom from any reoperation was 86.4% (95% confidence interval, 83.6-88.7) and 65.4% (95% confidence interval, 59.8-70.4) at 10 and 20 years, respectively. Postoperative right ventricular outflow tract peak gradient of 25 mm Hg or greater correlated with reoperation. Propensity score-matched analysis demonstrated that freedom from pulmonary valve replacement at 15 years was higher in the pulmonary valve preservation group compared with the transannular patch group (98.2% vs 78.4%, P = .004). Freedom from reoperation for right ventricular outflow tract obstruction at 15 years was lower in the pulmonary valve preservation group compared with the transannular patch group (P = .006).

CONCLUSIONS

The long-term outcomes of tetralogy of Fallot repair are excellent. A postoperative right ventricular outflow tract peak gradient less than 25 mm Hg appears to be optimal to prevent reoperation. If the pulmonary valve size is suitable, pulmonary valve preservation reduces the risk of pulmonary valve replacement, yet increases the reoperation rate for right ventricular outflow tract obstruction.

Для цитирования: Ishigami Shuta, Ye Xin Tao, Buratto Edward, Ivanov Yaroslav, Chowdhuri Kuntal Roy, Fulkoski Nick, Robertson Terry, Davies Ben, Brizard Christian P, Konstantinov Igor E. Long-term outcomes of tetralogy of Fallot repair: A 30-year experience with 960 patients.. The Journal of thoracic and cardiovascular surgery. 2023. DOI: 10.1016/j.jtcvs.2023.04.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.