MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc · 2012

Type II decompression sickness in a hyperbaric inside attendant.

Johnson-Arbor Kelly

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Decompression sickness (DCS) of an inside attendant (IA) is rarely encountered in hyperbarics. This report describes an IA who developed Type II DCS after a routine hyperbaric exposure.

CASE REPORT: A 50-year-old male complained of lower extremity weakness and paresthesias after serving as an IA during a hyperbaric treatment to 40 fsw (122.52 kPa). Within 10 minutes after the conclusion of the treatment, the IA experienced irritability and confusion, and was unable to walk. Physical examination revealed decreased sensation below the T7 level, and decreased strength in the lower extremities. Type II DCS was diagnosed, and the IA was recompressed to 60 fsw (183.78 kPa) on a U.S. Navy Treatment Table 6, which resulted in improvement of his symptoms. Transthoracic echocardiography with bubble study performed 16 months after the event demonstrated a large patent foramen ovale (PFO).

DISCUSSION: Increased age, decreased physical fitness and the undiagnosed PFO may have predisposed this attendant to developing DCS.

CONCLUSIONS

Although rare, DCS may occur in IAs. Routine monitoring and reporting of the long-term health of hyperbaric IAs should be considered by hyperbaric facilities and medical directors in order to further understand the characteristics of DCS and other hyperbaric-related conditions in these workers.

Для цитирования: Johnson-Arbor Kelly. Type II decompression sickness in a hyperbaric inside attendant.. Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc. 2012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.