MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.3c00701

Медицинская библиотека · Analytical chemistry · 2023

Nanoarchitectonics-Assisted Simultaneous Fluorescence Detection of Urinary Dual miRNAs for Noninvasive Diagnosis of Prostate Cancer.

Jiang Pengjun, Bai Yunjin, Yan Li, Feng Pan, Huang Ke, Chen Jie, Chen Piaopiao

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Herein, we report a fluorescence strategy for the homogeneous and simultaneous analysis of urine miRNA-375 and miRNA-148a. The target miRNAs in urine bonded the devised dumbbell-shaped "C-Ag+-C" and "T-Hg2+-T" hairpin structures that could trigger cascade enzyme-free amplification. Then, the fluorescent CdTe quantum dots (QDs) and carbon dots (CDs) could selectively recognize Ag+ and Hg2+, to quantify the dual miRNAs concurrently. Under optimized conditions, the linear range was from 0.1 to 1000 fM and the limits of detection (LOD) for dual miRNAs reached 30 and 25 aM, respectively. The practicality was further evaluated with 45 clinical urine samples including prostate cancer (PC) and other patients, and the results were consistent with the clinical polymerase chain reaction (PCR) kit and ultrasonic and pathological findings. The receiver operating characteristic (ROC) curve analysis showed that the estimates of the area under the curve (AUC) were 0.739 for the serum prostate-specific antigen (PSA) and 0.941 for miRNA-375 and 0.946 for miRNA-148a. The sensitivity and specificity reached 75 and 100% for miRNA-375 and 71 and 94% for miRNA-148a, respectively, which was better than serum PSA. This strategy constructed a reliable system for dual miRNA detection in urine samples and proposed new insights into the rapid and noninvasive diagnosis of PC.

Для цитирования: Jiang Pengjun, Bai Yunjin, Yan Li, Feng Pan, Huang Ke, Chen Jie, Chen Piaopiao. Nanoarchitectonics-Assisted Simultaneous Fluorescence Detection of Urinary Dual miRNAs for Noninvasive Diagnosis of Prostate Cancer.. Analytical chemistry. 2023. DOI: 10.1021/acs.analchem.3c00701.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.