MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjo.2004.046383

Медицинская библиотека · The British journal of ophthalmology · 2004

Frequency doubling technology perimetry in non-arteritic ischaemic optic neuropathy with altitudinal defects.

Girkin C A, McGwin G, DeLeon-Ortega J

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

AIM: To determine if frequency doubling technology perimetry (FDT) is more sensitive to optic nerve injury in non-arteritic ischaemic optic neuropathy (NAION) than standard automated perimetry (SAP).

METHODS

Charts from 18 patients (20 eyes) with NAION with altitudinal defects who underwent a complete neuro-ophthalmic examination, SAP, and FDT were reviewed. The extent of damage as determined by SAP, FDT, and clinical estimation of the regional extent of optic disc pallor was compared. 10 subjects (20 eyes) with normal ocular examinations and full appearing optic nerve heads were included as a control group.

RESULTS

FDT demonstrated more extensive visual field defects in the relatively intact hemifield on SAP (proportion of locations at 5% or worse in the total deviation plot was 8.7% (SD 6.2%) for SAP and 38.3% (39.5%) for FDT p<0.0027). 16 of 20 eyes with altitudinal NAION demonstrated diffuse optic disc pallor. 11 of these eyes with diffuse pallor demonstrated significant defects in both hemifields using FDT, while only two eyes demonstrated diffuse damage using SAP. Correspondence between the extent of optic disc pallor and the extent of visual scotoma was higher for FDT (85%) than with SAP (40%).

CONCLUSION

FDT appears more sensitive to axonal injury reflected by the extent of optic disc pallor in altitudinal NAION than SAP and in some patients reveals visual dysfunction in the hemifield that appeared relatively uninvolved when evaluated using SAP.

Для цитирования: Girkin C A, McGwin G, DeLeon-Ortega J. Frequency doubling technology perimetry in non-arteritic ischaemic optic neuropathy with altitudinal defects.. The British journal of ophthalmology. 2004. DOI: 10.1136/bjo.2004.046383.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.