MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-021-03772-9

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2021

Leave it or fix it? How fixation of a small posterior malleolar fragment neutralizes rotational forces in trimalleolar fractures.

Evers Julia, Fischer Maren, Raschke Michael, Riesenbeck Oliver, Milstrey Alexander, Gehweiler Dominic, Gueorguiev Boyko, Ochman Sabine

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

This study investigated the effects of a small posterior malleolar fragment (PMF), containing less than 25% articular surface area, on ankle joint stability via computed tomography (CT) scanning under full weight bearing in a human cadaveric ankle fracture model.

MATERIALS AND

METHODS

A trimalleolar fracture with a PMF of less than 25% articular surface area was created in 6 pairs of fresh-frozen human cadaveric lower legs. The specimens were randomized into 2 groups stabilized by internal fixation including a positioning screw for syndesmotic reconstruction. In Group I the PMF was addressed by direct screw osteosynthesis, whereas in Group II the fragment was not fixed. Six predefined distances within the ankle were measured under axial loading. CT scans of each specimen were performed in intact and fixated states in neutral position, dorsiflexion and plantar-flexion of the ankle.

RESULTS

In plantar-flexion, significant differences were detected between the groups with regard to rotational instability. Group II demonstrated a significantly increased inward rotation of the fibula compared with Group I. No significant differences were detected between the groups for each one of the measured distances in any of the three foot positions.

CONCLUSIONS

Additional reduction and fixation of a small PMF seems to neutralize rotational forces in the ankle more effectively than a sole syndesmotic screw. Clinically, this becomes relevant in certain phases of the gait cycle. Direct screw osteosynthesis of a small PMF stabilizes the ankle more effectively than a positioning screw.

Для цитирования: Evers Julia, Fischer Maren, Raschke Michael, Riesenbeck Oliver, Milstrey Alexander, Gehweiler Dominic, Gueorguiev Boyko, Ochman Sabine. Leave it or fix it? How fixation of a small posterior malleolar fragment neutralizes rotational forces in trimalleolar fractures.. Archives of orthopaedic and trauma surgery. 2021. DOI: 10.1007/s00402-021-03772-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.