DOI 10.1016/s0029-7844(98)00554-7
Maternal serum screening for fetal trisomy 18: a comparison of fixed cutoff and patient-specific risk protocols.
Аннотация
OBJECTIVE
To compare the effectiveness of two widely used protocols for second-trimester screening for fetal trisomy 18.
METHODS
Second-trimester screening results for 41,565 women were reviewed to determine whether pregnancies could be considered to be at high risk for trisomy 18. The screening test was considered positive if either maternal serum concentrations of alpha-fetoprotein (MSAFP), hCG, and unconjugated estriol (E3) fell below defined levels, or the second-trimester patient-specific risk (based on maternal age and serum analytes) was greater than 1:100. Detection rates, false-positive rates, and pregnancy outcomes for the two protocols were compared.
RESULTS
The fixed-cutoff method showed a 23% detection rate and a 0.19% false-positive rate for trisomy 18. These low rates were in close agreement with a theoretical expectation for fixed-cutoff trisomy 18 screening. The risk-based approach resulted in a 69% detection rate and a 0.45% false-positive rate. Both methods identified pregnancies with other fetal anomalies.
CONCLUSION
Overall, the risk-based method is more effective than the fixed-cutoff approach to trisomy 18 screening.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.