MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/tp.0000000000005818

Медицинская библиотека · Transplantation · 2026

Determinants of Baseline Lung Allograft Dysfunction and its Long-term Impact on Pulmonary Function After Bilateral Lung Transplantation.

Revilla-Lopez Eva, Barquero-Dueñas Paula, Andrade-Bustamante Arianna, Salvador-Fernandez Sara, Lopez-Meseguer Manuel, Cantero-Acedo Alvaro, Romero-Espinosa Cristina Alexandra, Arbiol-Urquizu Marcos, Soto-Fernandez Luis Daniel, Monforte Victor, Villar Ana, Gómez-Ollés Susana, Vos Robin, Berastegui Cristina, Sáez-Giménez Berta

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Lung transplantation (LT) is the definitive treatment for selected end-stage lung diseases, yet some recipients fail to achieve normal pulmonary function posttransplant, a condition known as baseline lung allograft dysfunction (BLAD). Its causes and long-term outcomes remain incompletely understood.

METHODS

We retrospectively analyzed all adult bilateral LT performed between 2014 and 2019, with follow-up through December 2024. BLAD was defined as failure to achieve forced expiratory volume in 1 s and/or forced vital capacity ≥80% predicted within the first post-LT year. Multivariable logistic regression identified risk factors, and Cox and linear mixed-effects models assessed associations with survival, chronic lung allograft dysfunction (CLAD), and lung function trajectories.

RESULTS

Among 325 recipients, BLAD occurred in 65.5% and was independently associated with reduced survival (hazard ratio, 5.25; 95% confidence interval, 3.84-7.18; P  < 0.001). BLAD was associated with increased CLAD risk in the overall cohort (hazard ratio, 1.42; 95% confidence interval, 1.00-2.00; P  = 0.047), although this association was attenuated after excluding recipients with structural or mechanical causes of reduced spirometry. Risk factors included higher body mass index, longer intensive care unit stay, bronchial stenosis, and older donor age. Over 5 y, BLAD recipients exhibited slower spirometry decline than recipients achieving normal baseline function, whereas CLAD was the main determinant of long-term functional deterioration.

CONCLUSIONS

BLAD is common after LT and is associated with increased mortality and lower long-term pulmonary function. The BLAD-CLAD association may be partly confounded by structural or mechanical causes of reduced spirometry, supporting BLAD as a heterogeneous early post-LT phenotype.

Для цитирования: Revilla-Lopez Eva, Barquero-Dueñas Paula, Andrade-Bustamante Arianna, Salvador-Fernandez Sara, Lopez-Meseguer Manuel, Cantero-Acedo Alvaro, Romero-Espinosa Cristina Alexandra, Arbiol-Urquizu Marcos, Soto-Fernandez Luis Daniel, Monforte Victor, Villar Ana, Gómez-Ollés Susana, Vos Robin, Berastegui Cristina, Sáez-Giménez Berta. Determinants of Baseline Lung Allograft Dysfunction and its Long-term Impact on Pulmonary Function After Bilateral Lung Transplantation.. Transplantation. 2026. DOI: 10.1097/tp.0000000000005818.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.