Chest CT at X-Ray Dose Using a Noise-Mitigating Weighted Projection: The Thoracic Tomogram. Diagnostic Performance for Pneumonia Detection in Hemato-Oncology Patients.

Sanchez Tijmes Felipe, Kandel Sonja, Kavanagh John, Carey Sean, May Mary, Chen Shiyi, Mattsson Jonas, Rogalla Patrik

СтатьяПеревод в очереди

Аннотация

PURPOSE: To compare the diagnostic performance of a thick-slab reconstruction obtained from an ultra-low-dose CT (termed thoracic tomogram) with standard-of-care low-dose CT (SOC-CT) for rapid interpretation and detection of pneumonia in hemato-oncology patients.

METHODS

Hemato-oncology patients with a working diagnosis of pneumonia underwent an SOC-CT followed by an ultra-low-dose CT, from which the thoracic tomogram (TT) was reconstructed. Three radiologists evaluated the TT and SOC-CT in the following categories: (I) infectious/inflammatory opacities, (II) small airways infectious/inflammatory changes, (III) atelectasis, (IV) pleural effusions, and (V) interstitial abnormalities. The TT interpretation time and radiation dose were recorded. Sensitivity, specificity, diagnostic accuracy, ROC, and AUC were calculated with the corresponding power analyses. The agreement between TT and SOC-CT was calculated by Correlation Coefficient for Repeated Measures (CCRM), and the Shrout-Fleiss intra-class correlations test was used to calculate interrater agreement.

RESULTS

Forty-seven patients (mean age 58.7 ± 14.9 years; 29 male) were prospectively enrolled. Sensitivity, specificity, accuracy, AUC, and Power for categories I/II/III/IV/V were: 94.9/99/97.9/0.971/100, 78/91.2/86.5/0.906/100, 88.6/100/97.2/0.941/100, 100/99.2/99.3/0.995/100, and 47.6/100/92.2/0.746/87.3. CCRM between TT and SOC-CT for the same categories were .97/.81/.92/.96/.62 with an interobserver agreement of .93/.88/.82/.96/.61. Mean interpretation time was 18.6 ± 5.4 seconds. The average effective radiation dose of TT was similar to a frontal and lateral chest X-ray (0.27 ± 0.08 vs 1.46 ± 0.64 mSv for SOC-CT; P < .01).

CONCLUSION

Thoracic tomograms provide comparable diagnostic information to SOC-CT for the detection of pneumonia in immunocompromised patients at one-fifth of the radiation dose with high interobserver agreement.

Для цитирования: Sanchez Tijmes Felipe, Kandel Sonja, Kavanagh John, Carey Sean, May Mary, Chen Shiyi, Mattsson Jonas, Rogalla Patrik. Chest CT at X-Ray Dose Using a Noise-Mitigating Weighted Projection: The Thoracic Tomogram. Diagnostic Performance for Pneumonia Detection in Hemato-Oncology Patients.. Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes. 2024. DOI: 10.1177/08465371231215670.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.