Morikawa Satoru, Harahap Indra Sari Kusuma, Kaszynski Richard Hideki, Yamamoto Tomoto, Pramudya Dian Kesuma, Pham Huyen Thi Van, Hartomo Tri Budi, Lee Myeong Jin, Morioka Ichiro, Nishimura Noriyuki, Yokoyama Naoki, Ueno Yasuhiro, Matsuo Masafumi, Nishio Hisahide

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

AIM: Spinal muscular atrophy (SMA) is a well-defined autosomal recessive neuromuscular disorder caused by mutations in the survival motor neuron 1 (SMN1) gene. The most frequently observed mutation is a deletion of exon 7, which has been documented in >95% of SMA patients. A novel technique for detecting mutations known as high-resolution melting analysis (HRMA) has rapidly become the tool of choice for screening pathogenic genetic variants. In the present study, we attempt to validate the applicability of HRMA to the detection of exon 7 deletions and other intragenic mutations in SMN1.

RESULTS

Three primer sets were adopted in our HRMA screening for deletion of SMN1 exon 7. In screening attempts utilizing two primer sets, the results of HRMA were not compatible with those obtained by polymerase chain reaction-restriction fragment length polymorphism. Therefore, we applied a modified protocol using revised primer sets, which resulted in an absolute compatibility of results between HRMA and polymerase chain reaction-restriction fragment length polymorphism. With regard to screenings for intragenic mutations in SMN1 exon 3, two primer sets were adopted for use in HRMA. In the initial HRMA screening using the first primer set, we failed to identify any intragenic mutations; however, when using a revised primer set, HRMA successfully detected the presence of a c.275G>C mutation.

CONCLUSION

HRMA is a simple but versatile tool to add to the existing arsenal of diagnostic techniques that could aid clinicians/researchers in diagnosing SMA. However, as we demonstrate in the present study, the design and selection of primers is of monumental importance in ensuring the successful application of HRMA to screening for pathogenic variants.

Для цитирования: Morikawa Satoru, Harahap Indra Sari Kusuma, Kaszynski Richard Hideki, Yamamoto Tomoto, Pramudya Dian Kesuma, Pham Huyen Thi Van, Hartomo Tri Budi, Lee Myeong Jin, Morioka Ichiro, Nishimura Noriyuki, Yokoyama Naoki, Ueno Yasuhiro, Matsuo Masafumi, Nishio Hisahide. Diagnosis of spinal muscular atrophy via high-resolution melting analysis symmetric polymerase chain reaction without probe: a screening evaluation for SMN1 deletions and intragenic mutations.. Genetic testing and molecular biomarkers. 2011. DOI: 10.1089/gtmb.2010.0237.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.