MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvc.2009.09.004

Медицинская библиотека · Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology · 2010

Echocardiographic assessment of left ventricular geometry and the mitral valve apparatus in cats with hypertrophic cardiomyopathy.

Schober Karsten, Todd Amanda

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

This retrospective study addressed the general hypothesis that abnormalities of the mitral valve apparatus are common in cats with idiopathic hypertrophic cardiomyopathy (HCM) and contribute to dynamic obstruction of the left ventricular outflow tract (LVOT).

ANIMALS, MATERIALS AND

METHODS

106 cats (28 controls and 78 with HCM) had transthoracic two-dimensional and Doppler echocardiography performed with quantification of 33 variables. Three groups of cats (control [Group-1], HCM without obstruction [Group-2], and HCM with obstruction [Group-3]) were identified and compared by analysis of variance, chi(2) analysis, and correlation analysis.

RESULTS

Cats in Group-3 had more LV and papillary muscle hypertrophy, increased length of the anterior mitral valve leaflet, and a higher prevalence of false tendons in the LVOT compared to cats in Group-2 (P < or = 0.05). The length of the anterior mitral valve leaflet was correlated to the severity of dynamic obstruction (P < or = 0.05) and the magnitude of LV hypertrophy (P < or = 0.001). Systolic anterior motion of chordae tendineae (CAM) was observed in 16% of control cats and >50% of cats with HCM (P < or = 0.05).

CONCLUSIONS

Abnormalities of the mitral valve are common in cats with HCM suggesting a possible role in the pathogenesis of dynamic outflow tract obstruction.

Для цитирования: Schober Karsten, Todd Amanda. Echocardiographic assessment of left ventricular geometry and the mitral valve apparatus in cats with hypertrophic cardiomyopathy.. Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology. 2010. DOI: 10.1016/j.jvc.2009.09.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.