MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.gastro.2021.07.004

Медицинская библиотека · Gastroenterology · 2021

Value of pH Impedance Monitoring While on Twice-Daily Proton Pump Inhibitor Therapy to Identify Need for Escalation of Reflux Management.

Gyawali C Prakash, Tutuian Radu, Zerbib Frank, Rogers Benjamin D, Frazzoni Marzio, Roman Sabine, Savarino Edoardo, de Bortoli Nicola, Vela Marcelo F, Sifrim Daniel

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND AND AIMS: Acid exposure time (AET) and reflux episode thresholds from the Lyon Consensus may not apply for pH impedance studies performed while on proton pump inhibitor (PPI) therapy. We aimed to determine metrics from "on PPI" pH impedance studies predicting need for escalation of therapy.

METHODS

De-identified pH impedance studies performed while on twice-daily PPI (Diversatek, Boulder, CO) in healthy volunteers (n = 66, median age 37.5 years, 43.9% female), and patients with proven gastroesophageal reflux disease (GERD) (European heartburn-predominant cohort: n = 43, median age 57.0 years, 55.8% female; North American regurgitation-predominant cohort: n = 42, median age 41.6 years, 42.9% female) were analyzed. Median values and interquartile ranges for pH impedance metrics in healthy volunteers were compared with proven GERD patients with and without 50% symptom improvement on validated measures. Receiver operating characteristic (ROC) analyses identified optimal thresholds predicting symptom response.

RESULTS

Both conventional and novel reflux metrics were similar between PPI responders and nonresponders (P ≥ .1 for each) despite differences from healthy volunteers. Combinations of metrics associated with conclusively abnormal reflux burden (AET >4%, >80 reflux episodes) were seen in 32.6% and 40.5% of heartburn and regurgitation-predominant patients, respectively, 57.1% and 82.4% of whom reported nonresponse; and 85% with these metrics improved with invasive GERD management. On ROC analysis, AET threshold of 0.5% modestly predicted nonresponse (sensitivity, 0.62; specificity, 0.51; P = .22), and 40 reflux episodes had better performance characteristics (sensitivity, 0.80; specificity, 0.51; P = .002); 79% with these metrics improved with invasive GERD management.

CONCLUSION

Combinations of abnormal "on PPI" pH impedance metrics are associated with PPI nonresponse in proven GERD patients, and can be targeted for treatment escalation, including surgery, particularly in regurgitation-predominant GERD.

Для цитирования: Gyawali C Prakash, Tutuian Radu, Zerbib Frank, Rogers Benjamin D, Frazzoni Marzio, Roman Sabine, Savarino Edoardo, de Bortoli Nicola, Vela Marcelo F, Sifrim Daniel. Value of pH Impedance Monitoring While on Twice-Daily Proton Pump Inhibitor Therapy to Identify Need for Escalation of Reflux Management.. Gastroenterology. 2021. DOI: 10.1053/j.gastro.2021.07.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.