Interdonor incompatibility due to anti-Kell antibody undetectable by automated antibody screening.

West N C, Jenkins J A, Johnston B R, Modi N

Клинический случайСтатьяПеревод в очереди

Аннотация

A unit of whole donor blood, the plasma of which contained anti-Kell antibody, was transfused into a Kell-negative patient who had received a unit of Kell-positive blood 4 weeks previously. A haemolytic transfusion reaction ensued. The antibody had gone undetected in routine automated screening of the donor blood. Automated antibody detection techniques do not offer reliable detection of anti-Kell antibodies.

Для цитирования: West N C, Jenkins J A, Johnston B R, Modi N. Interdonor incompatibility due to anti-Kell antibody undetectable by automated antibody screening.. Vox sanguinis. 1986. DOI: 10.1111/j.1423-0410.1986.tb04873.x.