MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acsami.6b03256

Медицинская библиотека · ACS applied materials & interfaces · 2016

Chemiresistive Electronic Nose toward Detection of Biomarkers in Exhaled Breath.

Moon Hi Gyu, Jung Youngmo, Han Soo Deok, Shim Young-Seok, Shin Beomju, Lee Taikjin, Kim Jin-Sang, Lee Seok, Jun Seong Chan, Park Hyung-Ho, Kim Chulki, Kang Chong-Yun

СтатьяПеревод в очереди

Аннотация

Detection of gas-phase chemicals finds a wide variety of applications, including food and beverages, fragrances, environmental monitoring, chemical and biochemical processing, medical diagnostics, and transportation. One approach for these tasks is to use arrays of highly sensitive and selective sensors as an electronic nose. Here, we present a high performance chemiresistive electronic nose (CEN) based on an array of metal oxide thin films, metal-catalyzed thin films, and nanostructured thin films. The gas sensing properties of the CEN show enhanced sensitive detection of H2S, NH3, and NO in an 80% relative humidity (RH) atmosphere similar to the composition of exhaled breath. The detection limits of the sensor elements we fabricated are in the following ranges: 534 ppt to 2.87 ppb for H2S, 4.45 to 42.29 ppb for NH3, and 206 ppt to 2.06 ppb for NO. The enhanced sensitivity is attributed to the spillover effect by Au nanoparticles and the high porosity of villi-like nanostructures, providing a large surface-to-volume ratio. The remarkable selectivity based on the collection of sensor responses manifests itself in the principal component analysis (PCA). The excellent sensing performance indicates that the CEN can detect the biomarkers of H2S, NH3, and NO in exhaled breath and even distinguish them clearly in the PCA. Our results show high potential of the CEN as an inexpensive and noninvasive diagnostic tool for halitosis, kidney disorder, and asthma.

Для цитирования: Moon Hi Gyu, Jung Youngmo, Han Soo Deok, Shim Young-Seok, Shin Beomju, Lee Taikjin, Kim Jin-Sang, Lee Seok, Jun Seong Chan, Park Hyung-Ho, Kim Chulki, Kang Chong-Yun. Chemiresistive Electronic Nose toward Detection of Biomarkers in Exhaled Breath.. ACS applied materials & interfaces. 2016. DOI: 10.1021/acsami.6b03256.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.