MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.31498

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2025

Validation of a Novel Computational Fluid Dynamics Based Method for Assessing Intracoronary Flow: Combining Coronary Angiography and Fractional Flow Reserve.

Xie Xinzhou, Li Na, Yu Tiantong, Pu Wenjun, Lin Heqiang, Li Xiang, Li Guoquan, Li Chengxiang, Chen Yan, Lian Kun

СтатьяВалидационное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

With a 3D model reconstructed from coronary angiography, intracoronary blood flow can be calculated using a computational fluid dynamics (CFD) model with fractional flow reserve (FFR) measured pressure as boundary conditions.

AIMS: The aim of this study is to investigate the clinical feasibility of this method by evaluating its ability to identify myocardial ischemia diagnosed by SPECT myocardial perfusion imaging (MPI).

METHODS

Patients who underwent both SPECT-MPI and coronary angiography with FFR within 1 week were enrolled. Based on the summed stress score (SSS) and summed difference score (SDS) of SPECT MPI, myocardial ischemia in individual coronary territories was identified. Mean flow rate (Q), total flow resistance (TFR), absolute microvascular resistance (AMR) and their corresponding resting state indices were computed using the novel CFD model.

RESULTS

A total of 52 patients with 53 vessels were investigated. Based on SPECT MPI, 23 patients (43.4%) were associated with abnormal MPI. Q was significant higher in normal MPI group compared with abnormal MPI group (59.68 ± 40.33 mL/min vs. 25.67 ± 21.55 mL/min, p < 0.001). The TFR were significantly lower in normal MPI group (TFR: 1898.25 ± 951.55 mmHg min/L vs. 4786.31 ± 3056.18 mmHg min/L, p < 0.001). The ROC-AUC of Q and TFR for discriminating normal and abnormal MPI were 0.876 (95% CI: 0.783-0.970, p < 0.001) and 0.854 (95% CI: 0.745-0.963, p < 0.001).

CONCLUSIONS

Intracoronary flow assessed by the novel CFD based method has shown promise in accurately identifying patients with abnormal SPECT MPI, offering a convenient and quantitative approach for assessing coronary physiology.

Для цитирования: Xie Xinzhou, Li Na, Yu Tiantong, Pu Wenjun, Lin Heqiang, Li Xiang, Li Guoquan, Li Chengxiang, Chen Yan, Lian Kun. Validation of a Novel Computational Fluid Dynamics Based Method for Assessing Intracoronary Flow: Combining Coronary Angiography and Fractional Flow Reserve.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2025. DOI: 10.1002/ccd.31498.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.