MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ccm.0000000000002500

Медицинская библиотека · Critical care medicine · 2017

Single-Operator Ultrasound-Guided Central Venous Catheter Insertion Verifies Proper Tip Placement.

Galante Ori, Slutsky Tzachi, Fuchs Lior, Smoliakov Alexander, Mizrakli Yuval, Novack Victor, Brotfein Evgeni, Klein Moti, Frenkel Amit, Koifman Leonid, Almog Yaniv

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To evaluate whether a single-operator ultrasound-guided, right-sided, central venous catheter insertion verifies proper placement and shortens time to catheter utilization.

DESIGN

Prospective observational study with historical controls.

SETTING

Adult ICUs.

PATIENTS: Sixty-four consecutive patients undergoing ultrasound-assisted right-sided central venous catheterization compared with 92 serial historic controls who had unassisted central catheter insertion at the same sites.

INTERVENTIONS: Subcostal transthoracic echocardiography during catheter insertion.

MEASUREMENTS AND MAIN

RESULTS

The primary outcome was the correct placement of the catheter tip determined by postprocedural chest radiography. The subclavian site was used in 41 patients (64%) (inserted without ultrasound guidance) in the ultrasound-assisted group and 62 (67%) in the control group, whereas the jugular vein was used in the remaining patients. The tip was accurately positioned in 59 of 68 patients (86.7%) in the ultrasound-assisted group compared with 51 of 94 (54.8%) in the control group (p < 0.001). The median time from end of the procedure to catheter utilization after chest radiography approval was 2.4 hours.

CONCLUSIONS

A single-operator ultrasound-guided central venous catheter insertion is effective in verifying proper tip placement and shortens time to catheter utilization.

Для цитирования: Galante Ori, Slutsky Tzachi, Fuchs Lior, Smoliakov Alexander, Mizrakli Yuval, Novack Victor, Brotfein Evgeni, Klein Moti, Frenkel Amit, Koifman Leonid, Almog Yaniv. Single-Operator Ultrasound-Guided Central Venous Catheter Insertion Verifies Proper Tip Placement.. Critical care medicine. 2017. DOI: 10.1097/ccm.0000000000002500.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.