MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fgstr.2024.1426687

Медицинская библиотека · Frontiers in gastroenterology (Lausanne, Switzerland) · 2024

Multiparametric quantitative MRI of healthy adult pancreas: correlations with gender and age.

Wang Lixia, Liang Lu, Zhang Jiyang, Wu Chaowei, Zhou Yang, Yu Yang, Zhang Chen, Jeon Christie Y, Jiang Tao, Gaddam Srinivas, Xie Yibin, Pandol Stephen J, Yang Qi, Li Debiao

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The pancreas plays an important role in the nutrition and metabolism of the whole body. Many disease processes including obesity, diabetes mellitus (DM), acute or chronic pancreatitis, and pancreatic carcinoma result in abnormality of pancreas morphology and function. Magnetic resonance imaging (MRI) provides quantitative parameters including T1, T2, and apparent diffusion coefficient (ADC) values for evaluating normal and abnormal pancreas. Based on the normal range of these quantitative parameters, pancreatic abnormality could be detected early. However, the range and the relationship of T1, T2, and ADC values with gender and age groups using the same dataset have not been explored.

PURPOSE: To establish the ranges of MRI tissue and functional parameters, including T1, T2, and ADC values, in healthy adult pancreas and their correlations with gender, subregion, and age.

MATERIALS AND

METHODS

The T1, T2, and ADC values of healthy pancreas in 86 adults were measured using a 3.0-T MRI scanner. The average T1, T2, and ADC values were obtained in the whole pancreas and subregions (head, neck, body, and tail). Their correlations with gender and age were investigated.

RESULTS

The T1, T2, and ADC values of the whole pancreas from all subjects were 870.07 ± 61.86 ms, 44.07 ± 6.14 ms, and 1.072 ± 0.212 × 10-3 mm2/s, respectively. T2 values were significantly different between genders (P < 0.05). No significant differences were found between subregions. The T1, T2, and ADC values differed significantly among the age groups (P < 0.05). The T1 value revealed a moderately positive correlation, while the T2 and ADC values displayed negative correlations with age (r = 0.31, -0.45, and -0.39, respectively). The combination of T1, T2, and ADC values achieved the highest AUC value and showed a significant difference compared to T1, T2, and ADC values alone in predicting age older than 45 years.

CONCLUSION

This study established the normal ranges of T1, T2, and ADC. We found that T2 is different between men and women, and T1, T2, and ADC are age-dependent. These results could be useful for quantitative MRI of pancreatic disease.

Для цитирования: Wang Lixia, Liang Lu, Zhang Jiyang, Wu Chaowei, Zhou Yang, Yu Yang, Zhang Chen, Jeon Christie Y, Jiang Tao, Gaddam Srinivas, Xie Yibin, Pandol Stephen J, Yang Qi, Li Debiao. Multiparametric quantitative MRI of healthy adult pancreas: correlations with gender and age.. Frontiers in gastroenterology (Lausanne, Switzerland). 2024. DOI: 10.3389/fgstr.2024.1426687.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.