MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s001340050430

Медицинская библиотека · Intensive care medicine · 1997

Blood pressure and heart rate changes during apnoea testing with or without CO2 insufflation.

Lang C J

Клиническое исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To determine changes of blood pressure and heart rate during apnoea testing for brain death without (A) and with (B) artificial CO2 augmentation.

DESIGN

Prospective, consecutive study.

SETTING

12 intensive care units in six towns in Northern Bavaria.

PATIENTS AND

PARTICIPANTS

A total of 55 apnoea tests were performed on 55 consecutive patients as part of the determination of brain death, 27 without and 28 with CO2 augmentation.

INTERVENTIONS: Apnoea tests following oxygenation with 100% O2 either after reduction of ventilatory volume (A) or after insufflation of CO2 during normoventilation (B). In each case, an arterial partial CO2 pressure of at least 8 kPa was documented.

RESULTS

All apnoea tests were without serious adverse effects (hypoxia, newly induced cardiac arrhythmia, cardiac asystole). An increased dopamine infusion rate was deemed necessary in only one case of group (A) because of marked systolic hypotension (< 8 kPa). Individual variation of systolic and diastolic blood pressure (BP) did not exceed + 62 to -46% and + 49 to -52% respectively, in group (A) and + 35 to -57% and + 40 to -48% respectively, in group (B). Variation of heart rate (HR) remained within the range + 24 to -31% in group (A) and + 37 to -22% in group (B).

CONCLUSIONS

HR varied less than BP. The possibility of a marked relative rise of fall of BP in group (A) was equal; in group (B) there was a lower change of rising BP. The chances for a rise or fall in HR were equal for the two groups. There was a tendency for less variation of cardiovascular parameters in group (B).

Для цитирования: Lang C J. Blood pressure and heart rate changes during apnoea testing with or without CO2 insufflation.. Intensive care medicine. 1997. DOI: 10.1007/s001340050430.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.