MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15266028241241494

Медицинская библиотека · Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2024

In-stent Restenosis After Stenting for Superior Mesenteric Artery Dissection Is Associated With Stent Landing Zone: From Clinical Prediction to Hemodynamic Mechanisms.

Mei Junhao, Yan Hui, Zhao Xi, Yuan Yuan, Su Haobo, Xue Tongqing, Jia Zhongzhi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To identify risk factors for in-stent restenosis (ISR) in patients undergoing stent placement for superior mesenteric artery dissection (SMAD) and to determine the hemodynamic mechanism underlying ISR.

METHODS

For this retrospective study, patients with SMAD who had ISR after stent placement were included in the ISR group, and age- and sex-matched patients with SMAD who did not experience ISR after stent placement were included in the control group. Clinical, imaging, and hemodynamic data were assessed. Multivariable regression was used to identify independent ISR risk factors. Structural and fluid dynamics simulations were applied to determine the hemodynamic mechanism underlying the occurrence of ISR.

RESULTS

The study population included 26 patients with ISR and 26 control patients. Multivariate analysis demonstrated that stent-to-vascular (S/V) ratio (odds ratio [OR], 1.14; 95% confidence interval [CI]: 1.00-1.29; p=0.045), stent proximal position >10 mm away from the SMA root (OR, 108.67; 95% CI: 3.09-3816.42; p=0.010), and high oscillatory shear index (OSI) area (OR, 1.25; 95% CI: 1.02-1.52; p=0.029) were predictors of ISR. In structural and fluid dynamics simulations, a stent proximal position near the abdominal aorta (AA) or entering into the AA reduced the contact area between the proximal struts of the stent and the vascular wall, and alleviated the distal lumen overdilation.

CONCLUSION

The S/V ratio, stent proximal position away from the SMA root (>10 mm), and high OSI area are independent risk factors for ISR in patients with SMAD undergoing stent placement. Deploying the proximal end of the stent near the AA or entering into the AA appears to improve the hemodynamic environment in the SMA lumen and ultimately reduce the risk of ISR.Clinical ImpactIn-stent restenosis is an uncommon but potentially catastrophic complication after stent placement for the management of superior mesenteric artery dissection. This study identified risk factors for in-stent restenosis and demonstrated that, as long as the stent can fully cover the dissection range, deploying the proximal end of the stent near the abdominal aorta or less entering into the abdominal aorta may reduce the risk of in-stent restenosis in this patient population.

Для цитирования: Mei Junhao, Yan Hui, Zhao Xi, Yuan Yuan, Su Haobo, Xue Tongqing, Jia Zhongzhi. In-stent Restenosis After Stenting for Superior Mesenteric Artery Dissection Is Associated With Stent Landing Zone: From Clinical Prediction to Hemodynamic Mechanisms.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2024. DOI: 10.1177/15266028241241494.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.