No relationship between right-to-left shunt with the severity of white matter hyperintensities.

Wan Chengqun, Zou Qian, Du Lilan, Wang Yangyang, Huang Zhenting, Cai Zhiyou

Многоцентровое исследованиеСтатьяПеревод в очереди

Аннотация

INTRODUCTION

Studies have shown that right-to-left shunt (RLS) is closely related to the occurrence of white matter hyperintensities (WMHs). Therefore, the detection of RLS is of great significance for the diagnosis and treatment of cerebral small vessel disease, especially for the prevention and treatment of WMHs. In this study, the c-TCD foaming experiment was selected to screen RLS, and evaluate the correlation between RLS and the severity of WMHs.

METHODS

We enrolled 334 migraineurs from a multicentre study from July 1 2019 and January 31 2020. Participants were all evaluated using contrast-enhanced transcranial Doppler, magnetic resonance imaging (MRI), and completed a questionnaire covering demographics, the main risk factors of vascular disease, and migraine status. RLS was classified into four grades (Grade 0 = Negative; Grade I = 1 ≤microbubbles (MBs)≤ 10; Grade II = MBs > 10 and no curtain; Grade III = curtain). Silent brain ischemic infarctions (SBI) and white matter hyperintensities (WMHs) were evaluated on MRI.

RESULTS

In the incidence of WMHs, we found a significant difference between patients with RLS and no RLS (p < 0.05). There is no relationship between different grades of RLS and the severity of WMHs (p > 0.05).

CONCLUSION

Overall, the positive rate of RLS is related to the incidence of WMHs. The different grades of RLS have no-relationship to do with the severity of WMHs.

Для цитирования: Wan Chengqun, Zou Qian, Du Lilan, Wang Yangyang, Huang Zhenting, Cai Zhiyou. No relationship between right-to-left shunt with the severity of white matter hyperintensities.. Clinical neurology and neurosurgery. 2023. DOI: 10.1016/j.clineuro.2023.107820.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.