MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.acvd.2014.07.045

Медицинская библиотека · Archives of cardiovascular diseases · 2014

Results of transcatheter pulmonary valvulation in native or patched right ventricular outflow tracts.

Malekzadeh-Milani Sophie, Ladouceur Magalie, Cohen Sarah, Iserin Laurence, Boudjemline Younes

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Although widely accepted worldwide, indications for percutaneous valve replacement are limited to treatment of dysfunction of prosthetic conduits inserted in the right ventricular outflow tract (RVOT). There has been little evaluation of the use of the Melody(®) valve for patched non-circular pulmonary pathways.

AIM: To evaluate the outcomes of Melody valve insertion in patients with a patched non-circular RVOT.

METHODS

We analysed procedural and outcomes data from 34 patients who underwent Melody valve implantation for a non-circular RVOT. RVOT preparation was done in all patients, using different techniques (conventional, Russian doll and/or PA jailing). Melody valve insertion was performed concomitantly in most patients.

RESULTS

All procedures were successful. Sixteen patients had complex additional procedures, including the jailing technique (n=5), the Russian doll technique (n=6) and multiple stent implantations (Russian jailing; n=5). The remaining patients were treated using the conventional technique with systematic prestenting. Three early complications occurred: one haemoptysis; one residual RVOT obstruction needing recatheterization 48 hours after percutaneous pulmonary valve implantation; and one stent embolization during advancement of the Ensemble(®) delivery system. The mean follow-up period was 2.6 years postprocedure. There was no stent fracture, migration or embolization. Two patients developed a significant paraprosthetic leak and one received a second Melody valve.

CONCLUSIONS

Careful patient selection, balloon sizing and RVOT preparation with prestenting are required to create a safe landing zone for the Melody valve. Short-term follow-up shows excellent results with no stent fracture or migration and appears promising.

Для цитирования: Malekzadeh-Milani Sophie, Ladouceur Magalie, Cohen Sarah, Iserin Laurence, Boudjemline Younes. Results of transcatheter pulmonary valvulation in native or patched right ventricular outflow tracts.. Archives of cardiovascular diseases. 2014. DOI: 10.1016/j.acvd.2014.07.045.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.