DOI 10.1016/j.jcrc.2016.02.021
Real-time ultrasound-guided infraclavicular axillary vein cannulation: A prospective study in mechanically ventilated critically ill patients.
Аннотация
PURPOSE: The main purpose of this study was to define the venipuncture and catheterization success rates and early mechanical complication rates of ultrasound-guided infraclavicular axillary vein cannulation.
MATERIALS AND
METHODS
We performed in-plane, real-time, ultrasound-guided infraclavicular axillary vein catheterizations under emergency and nonemergency conditions in mechanically ventilated, critically ill patients.
RESULTS
We performed 202 cannulation attempts. One hundred and twenty-six procedures (62.4%) were performed under emergency conditions. The puncture of the axillary vein was successful in 98.5% of patients, and the entire procedure success rate was 95.1% (95% confidence interval, 91.1%-97.6%). For the majority of patients (84.1%; P<.001, exact test), the venipuncture occurred during the first attempt. We noted a 22.4% overall complication rate, and most of the complications were malpositions (13.4%). We observed 8.5% of cases with potentially serious complications (puncture of the axillary artery and needle contact with the brachial plexus) and 1 case (0.5%) of pneumothorax. The puncture of the axillary artery occurred in 5 (2.5%) patients.
CONCLUSIONS
In-plane, real-time, ultrasound-guided, infraclavicular axillary vein cannulation in mechanically ventilated, critically ill patients is a safe and reliable method of central venous cannulation and can be considered to be a reasonable alternative to other central venous catheterization techniques.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.