OBJECTIVE

We report on the 1-year outcomes of fetuses who underwent thoracoamniotic shunting (TAS) with a double-basket catheter for fetal hydrothorax (FHT) using a national post-marketing surveillance registry.

METHODS

This surveillance study was conducted for cases enrolled between 2011 and 2019. Preoperative, operative, and postoperative findings and outcomes had to be reported through the national surveillance website.

RESULTS

Forty-three institutes enrolled 295 patients. In 60 patients, associated abnormalities were diagnosed after birth. Among the 235 patients with isolated hydrothorax, the survival rate at 1 year of age was 70.5%. Among these patients, 89% did not require oxygen or other respiratory support. The 1-year survival rate in complicated cases was 27%. Trisomy 21 was the most common associated problem (40%). Catheter associated problems, including dislocation (25%), obstruction (24%), and preterm rupture of the membranes (6%) were observed, but there were no severe maternal complications. TAS before 29.5 weeks of gestation (odds ratio [OR] 0.16) and skin edema and ascites (OR 0.06) were risk factors for death at one year, whereas appropriate shunt location for >28 days (OR 4.2) was a protective factor.

CONCLUSION

We report a favorable survival rate in fetuses with isolated FHT treated with this double-basket catheter.

Для цитирования: Takahashi Yuichiro, Ishii Keisuke, Ishikawa Hiroshi, Imai Kenji, Baba Kazunori, Sago Haruhiko. National registry of thoracoamniotic shunting using a double-basket catheter: A post-marketing surveillance registry of 295 patients with fetal hydrothorax.. Prenatal diagnosis. 2024. DOI: 10.1002/pd.6587.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.