MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mbp.0000000000000749

Медицинская библиотека · Blood pressure monitoring · 2025

Comparison of the head-up tilt test and the 10-minute NASA lean test for assessing blood pressure and heart rate responses in young individuals with postacute COVID-19 syndrome.

Sathaporn Nontanat, Timinkul Aomkhwan, Panwong Watjanarat, Pipatbanjong Parkpoom, Dangwisut Tanyasorn, Phusabsin Phimkan, Promjun Kotchaporn, Kluayhomthong Sujittra

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Individuals with postacute COVID-19 syndrome (PACS) typically exhibit abnormal hemodynamic responses during upright positioning, including orthostatic hypotension and postural orthostatic tachycardia syndrome. The 10-minute NASA lean test (NLT) has been suggested for this condition. However, no comparative study with the head-up tilt table test (HUTT) has been conducted. This study aimed to compare blood pressure and heart rate responses during the 10-minute duration of NLT and HUTT.

METHODS

Eighty young individuals (aged 22.0 ± 3.1 years) with PACS underwent both tests, with a 30-minute interval between tests. Systolic blood pressure (SBP), diastolic blood pressure (DBP), and heart rate (HR) were measured every minute, and the differences between supine and upright positions were analyzed.

RESULTS

There were no significant differences in SBP changes between HUTT and NLT (-7.8 ± 6.2 vs. -7.1 ± 7.5 mmHg) with a mean difference of -0.7 ± 9.0 mmHg. However, DBP changes were significantly lower in HUTT compared to NLT (-0.9 ± 6.4 vs. 1.5 ± 6.9 mmHg for NLT) with a mean difference of -2.4 ± 7.1 mmHg. Maximal HR was significantly lower in HUTT compared to NLT (92.0 ± 11.4 vs. 96.2 ± 10.8 bpm for NLT) with a mean difference of -4.2 ± 6.9 bpm. Additionally, HR changes were significantly lower in HUTT compared to NLT (21.5 ± 8.1 vs. 27.0 ± 9.0 bpm) with a mean difference of -5.4 ± 6.4 bpm.

CONCLUSION

The NLT demonstrated comparability with the HUTT in detecting SBP changes. However, clinical applications should consider differences in measuring DBP and HR changes.

Для цитирования: Sathaporn Nontanat, Timinkul Aomkhwan, Panwong Watjanarat, Pipatbanjong Parkpoom, Dangwisut Tanyasorn, Phusabsin Phimkan, Promjun Kotchaporn, Kluayhomthong Sujittra. Comparison of the head-up tilt test and the 10-minute NASA lean test for assessing blood pressure and heart rate responses in young individuals with postacute COVID-19 syndrome.. Blood pressure monitoring. 2025. DOI: 10.1097/mbp.0000000000000749.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.