MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1364/ao.49.005517

Медицинская библиотека · Applied optics · 2010

Improved field scanner incorporating parabolic optics. Part 2: Experimental verification and potential for volume scanning.

Liu Rui, Sun Zhen, Wang Shimiao, Liu Xin, Man Yuhong, Chen Meiwan, Liu Qian, Wang Chunyue

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To report the visual and topographic outcomes of two pulsed-light-accelerated CXL (A-CXL) protocols at a 12-month follow-up and their correlation with the corneal stromal demarcation line (DL) depth.

PATIENTS AND

METHODS

Retrospective comparative cohort of patients with documented progressive keratoconus were included. Two epi-off pulsed-light [1s on-1s off] A-CXL protocols were compared: irradiance 30*8 and 45*5:20 (fluence 7.2 J/cm2). UDVA, CDVA, spherical equivalent (SE), topographic astigmatism, Kmin, Kmax, Km, central corneal thickness (CCT), thinnest pachymetry (TCT) and endothelial cell density (ECD) were measured preoperatively and months 1, 3, 6 and 12 postoperative. Corneal DL was measured 1 month postoperatively using anterior segment optical coherence tomography.

RESULTS

Fifty eyes (27 patients): 22 eyes in group A-CXL (30*8), 28 eyes in group A-CXL (45*5:20). Mean age (years) was 19.04±4.71 and 20.32±4.57. DL depth (µm) at month 1 was 200.63±10.01 µm and 184.53±19.68 µm for group A-CXL (30*8) and group A-CXL (45*5:20), respectively (p<0.001). Significant improvement in CDVA, topographic astigmatism, Kmin, Kmax and Km was observed in both groups (no significant difference between groups) and no significant changes were observed in CCT, TCT and ECD with regard to baseline. Over 85% of the eyes in both protocols achieved stabilization or improvement in maximum K at the end of the follow-up. No significant correlations between DL and any visual or topographic outcomes were observed at 12 months.

CONCLUSION

No correlation between DL depth and visual or topographic outcomes was observed on either protocol. Although significant improvement on CDVA, topographic astigmatism, Kmin, Kmax and Km was observed in both groups at 12 months, further research is needed to assure safety and effectiveness at stabilizing keratoconus progression.

Для цитирования: Liu Rui, Sun Zhen, Wang Shimiao, Liu Xin, Man Yuhong, Chen Meiwan, Liu Qian, Wang Chunyue. Improved field scanner incorporating parabolic optics. Part 2: Experimental verification and potential for volume scanning.. Applied optics. 2010. DOI: 10.1364/ao.49.005517.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.