MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/17085381251325652

Медицинская библиотека · Vascular · 2025

An experimental study of a novel high-precision iliac vein pressure measuring device to evaluate iliac vein compression syndrome.

Liu Liguo, Dai Xiangchen, Zhang Xiujun, Huang Junjie, Zhao Ziyuan, Liu Cunfa

СтатьяПеревод в очереди

Аннотация

ObjectiveThis study aims to assess the clinical value of a novel high-precision iliac vein pressure measuring device to diagnose and treat iliac vein compression syndrome.MethodsA total of 38 patients with clinically confirmed iliac vein compression syndrome (all lesions on the left side) were selected. The iliac vein pressure and pressure recovery time (time taken for pressure to return to resting levels) were measured in four states: rest, affected limb elevation, ankle extension and flexion, and gastrocnemius muscle compression. Bilateral comparisons and pre- and post-treatment assessments were conducted.ResultsThe left iliac vein pressure in the four states (42.40 ± 16.08 mmH2O, 51.23 ± 17.63 mmH2O, 70.26 ± 25.55 mmH2O, and 111.47 ± 58.78 mmH2O) and pressure recovery time (25.57 ± 10.65 s) were significantly higher compared to the right iliac vein pressure (30.67 ± 7.46 mmH2O, 36.55 ± 8.59 mmH2O, 44.84 ± 11.17 mmH2O, and 52.96 ± 14.06 mmH2O) and recovery time (18.92 ± 21.07 s) (p = .000). The pressure in patients with left iliac occlusion (179.07 ± 31.64 mmH2O) was significantly higher than in patients with stenosis (79.91 ± 33.54 mmH2O) (p = .000). In eight patients who underwent intraluminal iliac venous therapy, postoperative pressure (37.29 ± 7.53 mmH2O, 44.74 ± 5.10 mmH2O, 53.76 ± 5.36 mmH2O, and 61.96 ± 7.27 mmH2O) and pressure recovery time (20.88 ± 5.67 s) significantly improved compared to preoperative measurements (50.53 ± 8.21 mmH2O, 60.03 ± 7.50 mmH2O, 96.88 ± 11.67 mmH2O, 177.11 ± 22.40 mmH2O, and 35.50 ± 6.95 s) (p < .01). Despite improvements, postoperative left iliac pressure remained significantly higher than the right iliac pressure in different states (p < .05). The left iliac vein pressure increased significantly during ankle extension and flexion, as well as gastrocnemius muscle compression compared to resting and elevated limb states (p < .05).ConclusionThe innovative high-precision iliac vein pressure measuring device enables rapid and accurate quantification of iliac vein pressure. As a functional diagnostic method, it holds considerable clinical value in diagnosing iliac vein compression syndrome and evaluating treatment efficacy.

Для цитирования: Liu Liguo, Dai Xiangchen, Zhang Xiujun, Huang Junjie, Zhao Ziyuan, Liu Cunfa. An experimental study of a novel high-precision iliac vein pressure measuring device to evaluate iliac vein compression syndrome.. Vascular. 2025. DOI: 10.1177/17085381251325652.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.