MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/bioengineering13091069

Медицинская библиотека · Bioengineering (Basel, Switzerland) · 2026

Evaluation of the Force System Acting Within an Orthodontic Appliance.

Roșianu Amelia Smaranda, Popa Dragoș Laurențiu, Buciu Gabriel, Petrescu Stelian-Mihai-Sever

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Implant-prosthetic rehabilitation of single-tooth edentulism often requires orthodontic reshaping of the potential implant-prosthetic space because its dimensions change due to the migration of adjacent teeth. In this context, it is very important to understand the force system generated by orthodontic arches in order to control tooth movement and to achieve, at the end of orthodontic treatment, the correct dimensions of the potential implant-prosthetic space for dental implant placement.

MATERIALS AND

METHODS

The study was based on CBCT images acquired from a 25-year-old female patient with maxillary and mandibular lateral edentulism. The images were processed using InVesalius and Geomagic to obtain a patient-specific three-dimensional reconstruction of the dento-maxillary structures. Orthodontic brackets, adhesive components, and round-section nickel-titanium archwires were subsequently modeled and positioned within a common three-dimensional coordinate system. The reconstructed geometry was used to extract local geometric parameters of the archwire. These parameters were subsequently introduced into a local equivalent Euler-Bernoulli beam formulation to estimate elastic force components and transverse reactions associated with the bracket-related points.

RESULTS

The study revealed an uneven distribution of forces along the orthodontic arches. For the upper arch, the elastic force values ranged from 0.044 to 0.383 N, and for the lower arch, from 0.050 to 0.308 N. The calculated reactions at the bracket components also varied depending on the orthodontic archwire geometry and the position of the support points.

CONCLUSIONS

Patient-specific three-dimensional reconstruction combined with a local analytical beam approximation provides a framework for estimating geometry-dependent elastic force components within an orthodontic appliance. The calculated values should be interpreted as equivalent local force estimates derived from the reconstructed geometry and not as a complete three-dimensional force-moment system.

Для цитирования: Roșianu Amelia Smaranda, Popa Dragoș Laurențiu, Buciu Gabriel, Petrescu Stelian-Mihai-Sever. Evaluation of the Force System Acting Within an Orthodontic Appliance.. Bioengineering (Basel, Switzerland). 2026. DOI: 10.3390/bioengineering13091069.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.