The Thoracic and cardiovascular surgeon · 2023
Sternal Pin Used to Close Sternum in Infants after Cardiac Surgery.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Xie Wen-Peng, Chen Xiu-Hua, Zhou Si-Jia, Chen Qiang, Cao Hua
Аннотация
OBJECTIVE: A retrospective study was conducted to explore the efficacy of bioabsorbable poly-L-lactic acid sternal pins in sternal closure in infants after cardiac surgery.
METHODS: A total of 170 infantile patients who underwent cardiac surgery were divided into the steel wire group (group A), the PDS cord group (group B), and the steel wire + sternal pin group (group C). The occurrence of the thoracic deformity was evaluated by vertebral index (VI), frontosagittal index (FSI), and Haller index (HI) values; the stability of the sternum was evaluated by detecting sternal dehiscence and displacement.
RESULTS: By comparing the absolute values of the differences in VI, FSI, and HI in the three groups, it was found that the difference values of VI and HI in group C were significantly lower than those in group B (p = 0.028 and 0.005). For the highest deformation index, the deformation rate of infants in group C before discharge and during the 1-year follow-up was lower than that in group A and group B (p = 0.009 and 0.002, respectively). The incidence of sternal displacement in group C was also significantly lower than that in groups A and B (p = 0.009 and 0.009). During the 1-year follow-up, there was no sternal dehiscence, and the sternum healed completely in the three groups.
CONCLUSION: The use of "steel wire + sternal pin" for sternal closure in infants after cardiac surgery can reduce the occurrence of sternal deformity, reduce anterior and posterior displacement of the sternum, and improve sternal stability.
METHODS: A total of 170 infantile patients who underwent cardiac surgery were divided into the steel wire group (group A), the PDS cord group (group B), and the steel wire + sternal pin group (group C). The occurrence of the thoracic deformity was evaluated by vertebral index (VI), frontosagittal index (FSI), and Haller index (HI) values; the stability of the sternum was evaluated by detecting sternal dehiscence and displacement.
RESULTS: By comparing the absolute values of the differences in VI, FSI, and HI in the three groups, it was found that the difference values of VI and HI in group C were significantly lower than those in group B (p = 0.028 and 0.005). For the highest deformation index, the deformation rate of infants in group C before discharge and during the 1-year follow-up was lower than that in group A and group B (p = 0.009 and 0.002, respectively). The incidence of sternal displacement in group C was also significantly lower than that in groups A and B (p = 0.009 and 0.009). During the 1-year follow-up, there was no sternal dehiscence, and the sternum healed completely in the three groups.
CONCLUSION: The use of "steel wire + sternal pin" for sternal closure in infants after cardiac surgery can reduce the occurrence of sternal deformity, reduce anterior and posterior displacement of the sternum, and improve sternal stability.