Медицинская библиотека · Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2004

Optimization of Gd-DTPA-enhanced balanced turbo field echo sequence in abdominal imaging: clinical application.

Nasu Katsuhiro, Kuroki Yoshifumi, Kuroki Seiko, Murakami Koji, Nawano Shigeru, Moriyama Noriyuki

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: We performed MRI examinations of patients in order to confirm the enhancement effect of the balanced turbo field echo (bTFE) sequence with centric view ordering and SPIR (SPIR-centric-bTFE) as mentioned in the prior paper, and to evaluate the actual image quality of this sequence.

MATERIALS AND

METHODS

The upper abdomens of 30 patients with various abdominal disorders were examined with the SPIR-centric-bTFE sequence before and after Gd-DTPA administration. To assess the enhancement effect of Gd-DTPA, ROI measurements were taken in the aorta, superior mesenteric artery, portal vein, liver and bile juice in the common bile duct in each patient both in pre- and postcontrast images. Visual evaluations were also carried out in order to depict the peripheral vessels in the peritoneal fat and the apparent brightness of the soft-tissue organs.

RESULTS

In all patients, the signal of the arteries after Gd-DTPA administration increased by about 50% compared with precontrast images. On the other hand, the veins and the liver showed a signal gain of less than 20% in postcontrast images. Consequently, only the signal of the arteries appeared enhanced in the postcontrast images. The visual evaluation revealed that postcontrast SPIR-centric-bTFE acquisition can depict the thin vessels clearly and the abdominal soft-tissue organs brightly.

CONCLUSION

The balanced turbo field echo sequence with centric view ordering and SPIR after Gd-DTPA injection was considered the most appropriate protocol when this sequence was employed for abdominal imaging.

Для цитирования: Nasu Katsuhiro, Kuroki Yoshifumi, Kuroki Seiko, Murakami Koji, Nawano Shigeru, Moriyama Noriyuki. Optimization of Gd-DTPA-enhanced balanced turbo field echo sequence in abdominal imaging: clinical application.. Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine. 2004. DOI: 10.2463/mrms.3.73.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.